PSIRNet: Deep Learning-based Free-breathing Rapid Acquisition Late Enhancement Imaging

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Atalik, Arda, Xue, Hui, Davies, Rhodri H., Treibel, Thomas A., Sodickson, Daniel K., Hansen, Michael S., Kellman, Peter
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917398364291072
author Atalik, Arda
Xue, Hui
Davies, Rhodri H.
Treibel, Thomas A.
Sodickson, Daniel K.
Hansen, Michael S.
Kellman, Peter
author_facet Atalik, Arda
Xue, Hui
Davies, Rhodri H.
Treibel, Thomas A.
Sodickson, Daniel K.
Hansen, Michael S.
Kellman, Peter
contents Purpose: To develop and evaluate a deep learning (DL) method for free-breathing phase-sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) cardiac MRI that produces diagnostic-quality images from a single acquisition over two heartbeats, eliminating the need for 8 to 24 motion-corrected (MOCO) signal averages. Materials and Methods: Raw data comprising 800,653 slices from 55,917 patients, acquired on 1.5T and 3T scanners across multiple sites from 2016 to 2024, were used in this retrospective study. Data were split by patient: 640,000 slices (42,822 patients) for training and the remainder for validation and testing, without overlap. The training and testing data were from different institutions. PSIRNet, a physics-guided DL network with 845 million parameters, was trained end-to-end to reconstruct PSIR images with surface coil correction from a single interleaved IR/PD acquisition over two heartbeats. Reconstruction quality was evaluated using SSIM, PSNR, and NRMSE against MOCO PSIR references. Two expert cardiologists performed an independent qualitative assessment, scoring image quality on a 5-point Likert scale across bright blood, dark blood, and wideband LGE variants. Paired superiority and equivalence (margin = 0.25 Likert points) were tested using exact Wilcoxon signed-rank tests at a significance level of 0.05 using R version 4.5.2. Results: Both readers rated single-average PSIRNet reconstructions superior to MOCO PSIR for dark blood LGE (conservative P = .002); for bright blood and wideband, one reader rated it superior and the other confirmed equivalence (all P < .001). Inference required approximately 100 msec per slice versus more than 5 sec for MOCO PSIR. Conclusion: PSIRNet produces diagnostic-quality free-breathing PSIR LGE images from a single acquisition, enabling 8- to 24-fold reduction in acquisition time.
format Preprint
id arxiv_https___arxiv_org_abs_2604_08781
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle PSIRNet: Deep Learning-based Free-breathing Rapid Acquisition Late Enhancement Imaging
Atalik, Arda
Xue, Hui
Davies, Rhodri H.
Treibel, Thomas A.
Sodickson, Daniel K.
Hansen, Michael S.
Kellman, Peter
Image and Video Processing
Artificial Intelligence
Computer Vision and Pattern Recognition
Signal Processing
Medical Physics
Purpose: To develop and evaluate a deep learning (DL) method for free-breathing phase-sensitive inversion recovery (PSIR) late gadolinium enhancement (LGE) cardiac MRI that produces diagnostic-quality images from a single acquisition over two heartbeats, eliminating the need for 8 to 24 motion-corrected (MOCO) signal averages. Materials and Methods: Raw data comprising 800,653 slices from 55,917 patients, acquired on 1.5T and 3T scanners across multiple sites from 2016 to 2024, were used in this retrospective study. Data were split by patient: 640,000 slices (42,822 patients) for training and the remainder for validation and testing, without overlap. The training and testing data were from different institutions. PSIRNet, a physics-guided DL network with 845 million parameters, was trained end-to-end to reconstruct PSIR images with surface coil correction from a single interleaved IR/PD acquisition over two heartbeats. Reconstruction quality was evaluated using SSIM, PSNR, and NRMSE against MOCO PSIR references. Two expert cardiologists performed an independent qualitative assessment, scoring image quality on a 5-point Likert scale across bright blood, dark blood, and wideband LGE variants. Paired superiority and equivalence (margin = 0.25 Likert points) were tested using exact Wilcoxon signed-rank tests at a significance level of 0.05 using R version 4.5.2. Results: Both readers rated single-average PSIRNet reconstructions superior to MOCO PSIR for dark blood LGE (conservative P = .002); for bright blood and wideband, one reader rated it superior and the other confirmed equivalence (all P < .001). Inference required approximately 100 msec per slice versus more than 5 sec for MOCO PSIR. Conclusion: PSIRNet produces diagnostic-quality free-breathing PSIR LGE images from a single acquisition, enabling 8- to 24-fold reduction in acquisition time.
title PSIRNet: Deep Learning-based Free-breathing Rapid Acquisition Late Enhancement Imaging
topic Image and Video Processing
Artificial Intelligence
Computer Vision and Pattern Recognition
Signal Processing
Medical Physics
url https://arxiv.org/abs/2604.08781