Options for RICH detectors based on silica aerogels for the high-momentum range

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Barnyakov, A. Yu., Bobrovnikov, V. S., Buzykaev, A. R., Chepelev, A. V., Efremov, R. A., Daniluyk, A. F., Katcin, A. A., Kravchenko, E. A., Kuyanov, I. A., Ofitserov, A. D., Ovtin, I. V.
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866911591199408128
author Barnyakov, A. Yu.
Bobrovnikov, V. S.
Buzykaev, A. R.
Chepelev, A. V.
Efremov, R. A.
Daniluyk, A. F.
Katcin, A. A.
Kravchenko, E. A.
Kuyanov, I. A.
Ofitserov, A. D.
Ovtin, I. V.
author_facet Barnyakov, A. Yu.
Bobrovnikov, V. S.
Buzykaev, A. R.
Chepelev, A. V.
Efremov, R. A.
Daniluyk, A. F.
Katcin, A. A.
Kravchenko, E. A.
Kuyanov, I. A.
Ofitserov, A. D.
Ovtin, I. V.
contents Nowadays, several projects of future colliding beam experiments are being considered in the world. Among them are the CEPC (Circular Electron Positron Collider) in China and the FCC (Future Circular Collider) at CERN (Switzerland). To perform experiments on flavor physics in the energy range of the projects an excellent particle identification up to momenta of 30 GeV/c is required. Several concepts of RICH detectors based on aerogel were considered and evaluated with the help of GEANT4 simulation: FARICH (Focusing Aerogel RICH) based on multilayer aerogel with maximal refractive index of 1.008, RICH with Fresnel lens based on aerogel with refractive index of 1.008, RICH based on transparent aerogel fibers with refractive index of 1.008. The results of the simulation are presented. Some results of beam tests at the BINP performed to validate GEANT4 simulation are presented as well.
format Preprint
id arxiv_https___arxiv_org_abs_2604_08962
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Options for RICH detectors based on silica aerogels for the high-momentum range
Barnyakov, A. Yu.
Bobrovnikov, V. S.
Buzykaev, A. R.
Chepelev, A. V.
Efremov, R. A.
Daniluyk, A. F.
Katcin, A. A.
Kravchenko, E. A.
Kuyanov, I. A.
Ofitserov, A. D.
Ovtin, I. V.
Instrumentation and Detectors
High Energy Physics - Experiment
Nowadays, several projects of future colliding beam experiments are being considered in the world. Among them are the CEPC (Circular Electron Positron Collider) in China and the FCC (Future Circular Collider) at CERN (Switzerland). To perform experiments on flavor physics in the energy range of the projects an excellent particle identification up to momenta of 30 GeV/c is required. Several concepts of RICH detectors based on aerogel were considered and evaluated with the help of GEANT4 simulation: FARICH (Focusing Aerogel RICH) based on multilayer aerogel with maximal refractive index of 1.008, RICH with Fresnel lens based on aerogel with refractive index of 1.008, RICH based on transparent aerogel fibers with refractive index of 1.008. The results of the simulation are presented. Some results of beam tests at the BINP performed to validate GEANT4 simulation are presented as well.
title Options for RICH detectors based on silica aerogels for the high-momentum range
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2604.08962