I Can't Believe TTA Is Not Better: When Test-Time Augmentation Hurts Medical Image Classification

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autor principal: Medeiros, Daniel Nobrega
Formato: Preprint
Publicado: 2026
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866911584171851776
author Medeiros, Daniel Nobrega
author_facet Medeiros, Daniel Nobrega
contents Test-time augmentation (TTA)--aggregating predictions over multiple augmented copies of a test input--is widely assumed to improve classification accuracy, particularly in medical imaging where it is routinely deployed in production systems and competition solutions. We present a systematic empirical study challenging this assumption across three MedMNIST v2 benchmarks and four architectures spanning three orders of magnitude in parameter count (21K to 11M). Our principal finding is that TTA with standard augmentation pipelines consistently degrades accuracy relative to single-pass inference, with drops as severe as 31.6 percentage points for ResNet-18 on pathology images. This degradation affects all architectures, including convolutional models, and worsens with more augmented views. The sole exception is ResNet-18 on dermatology images, which gains a modest +1.6%. We identify the distribution shift between augmented and training-time inputs--amplified by batch normalization statistics mismatch--as the primary mechanism. Our ablation studies show that augmentation strategy matters critically: intensity-only augmentations preserve more performance than geometric transforms, and including the original unaugmented image partially mitigates but does not eliminate the accuracy drop. These findings serve as a cautionary note for practitioners: TTA should not be applied as a default post-hoc improvement but must be validated on the specific model-dataset combination.
format Preprint
id arxiv_https___arxiv_org_abs_2604_09697
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle I Can't Believe TTA Is Not Better: When Test-Time Augmentation Hurts Medical Image Classification
Medeiros, Daniel Nobrega
Computer Vision and Pattern Recognition
Artificial Intelligence
I.4.9; I.5.4
Test-time augmentation (TTA)--aggregating predictions over multiple augmented copies of a test input--is widely assumed to improve classification accuracy, particularly in medical imaging where it is routinely deployed in production systems and competition solutions. We present a systematic empirical study challenging this assumption across three MedMNIST v2 benchmarks and four architectures spanning three orders of magnitude in parameter count (21K to 11M). Our principal finding is that TTA with standard augmentation pipelines consistently degrades accuracy relative to single-pass inference, with drops as severe as 31.6 percentage points for ResNet-18 on pathology images. This degradation affects all architectures, including convolutional models, and worsens with more augmented views. The sole exception is ResNet-18 on dermatology images, which gains a modest +1.6%. We identify the distribution shift between augmented and training-time inputs--amplified by batch normalization statistics mismatch--as the primary mechanism. Our ablation studies show that augmentation strategy matters critically: intensity-only augmentations preserve more performance than geometric transforms, and including the original unaugmented image partially mitigates but does not eliminate the accuracy drop. These findings serve as a cautionary note for practitioners: TTA should not be applied as a default post-hoc improvement but must be validated on the specific model-dataset combination.
title I Can't Believe TTA Is Not Better: When Test-Time Augmentation Hurts Medical Image Classification
topic Computer Vision and Pattern Recognition
Artificial Intelligence
I.4.9; I.5.4
url https://arxiv.org/abs/2604.09697