Analysis and Enhancement of Incremental-Quantity-Based Distance Protection With Grid-Forming Inverters

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Johansson, Henrik, Xing, Qianli, Taylor, Nathaniel, Wang, Xiongfei
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866914465013825536
author Johansson, Henrik
Xing, Qianli
Taylor, Nathaniel
Wang, Xiongfei
author_facet Johansson, Henrik
Xing, Qianli
Taylor, Nathaniel
Wang, Xiongfei
contents Grid-forming (GFM) inverters are expected in future inverter-dominated grids. In such grids, time-domain protection schemes, for example those based on instantaneous incremental quantities (IQs), are being advocated as potential solutions to the challenges faced by traditional phasor-based protection schemes, due to their ability to process nonlinear data. However, IQ-based protection uses the superposition principle; thus, linearity is still assumed in their application, while GFM inverters are nonlinear sources during faults. This paper proposes an analytical model to study the impact of GFM inverters on the relay-measured IQs. The model is validated with PSCAD/EMTDC simulations, and is used to investigate the interoperability of time-domain IQ-based distance protection with GFM inverters employing different current limiters. Results show that time-domain IQ-based distance protection demonstrates superior dependability for close-in faults compared to that of quadrilateral distance protection with GFM inverters, and it has the possibility to be secure for external faults when quadrilateral distance protection overreaches; however, tuning of its settings is hard to generalize for various sources and faults. Taking the observed interoperability issues into account, a trip criterion for dependable and secure time-domain IQ-based distance protection is proposed, which facilitates easy-to-tune and general settings for applications with GFM inverters.
format Preprint
id arxiv_https___arxiv_org_abs_2604_10129
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Analysis and Enhancement of Incremental-Quantity-Based Distance Protection With Grid-Forming Inverters
Johansson, Henrik
Xing, Qianli
Taylor, Nathaniel
Wang, Xiongfei
Systems and Control
Grid-forming (GFM) inverters are expected in future inverter-dominated grids. In such grids, time-domain protection schemes, for example those based on instantaneous incremental quantities (IQs), are being advocated as potential solutions to the challenges faced by traditional phasor-based protection schemes, due to their ability to process nonlinear data. However, IQ-based protection uses the superposition principle; thus, linearity is still assumed in their application, while GFM inverters are nonlinear sources during faults. This paper proposes an analytical model to study the impact of GFM inverters on the relay-measured IQs. The model is validated with PSCAD/EMTDC simulations, and is used to investigate the interoperability of time-domain IQ-based distance protection with GFM inverters employing different current limiters. Results show that time-domain IQ-based distance protection demonstrates superior dependability for close-in faults compared to that of quadrilateral distance protection with GFM inverters, and it has the possibility to be secure for external faults when quadrilateral distance protection overreaches; however, tuning of its settings is hard to generalize for various sources and faults. Taking the observed interoperability issues into account, a trip criterion for dependable and secure time-domain IQ-based distance protection is proposed, which facilitates easy-to-tune and general settings for applications with GFM inverters.
title Analysis and Enhancement of Incremental-Quantity-Based Distance Protection With Grid-Forming Inverters
topic Systems and Control
url https://arxiv.org/abs/2604.10129