A Wearable ECG Device for Differentiating Hypertrophic Cardiomyopathy from Acquired Left Ventricular Hypertrophy

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Li, Jiachen, Zhu, Hanyu, Kim, Edward, Li, Shihao, Cavanaugh, Katherine, Patel, Arpan, De Sirkar, Sovik, Hong, Mauricio, Li, Wei, Chen, Dongmei
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866918446357282816
author Li, Jiachen
Zhu, Hanyu
Kim, Edward
Li, Shihao
Cavanaugh, Katherine
Patel, Arpan
De Sirkar, Sovik
Hong, Mauricio
Li, Wei
Chen, Dongmei
author_facet Li, Jiachen
Zhu, Hanyu
Kim, Edward
Li, Shihao
Cavanaugh, Katherine
Patel, Arpan
De Sirkar, Sovik
Hong, Mauricio
Li, Wei
Chen, Dongmei
contents Hypertrophic Cardiomyopathy (HCM) is a genetic heart disease affecting approximately 1 in 500 people and is the leading cause of sudden cardiac death in young athletes. Current diagnostic methods -- cardiovascular magnetic resonance (CMR), echocardiography, and genetic testing -- are limited by high costs, operator dependency, or insufficient accuracy, while standard electrocardiogram (ECG) analysis cannot reliably distinguish HCM from acquired left ventricular hypertrophy (LVH). This paper presents a wearable ECG device paired with a classification algorithm that differentiates HCM from acquired LVH using ECG signals alone. The portable device integrates a 3-lead electrode system, an AD8232 signal conditioning module, an Arduino Nano 33 BLE microcontroller, and a lithium polymer battery. The algorithm extracts two quantitative indices -- HCM Index~1 and HCM Index~2 -- from each heartbeat and classifies patients via dual statistical thresholds. Validation on 483 LVH patients (PhysioNet) and 29 HCM patients (digitized clinical records) yields 75.86\% sensitivity, 99.17\% specificity, and an F1-score of 80.00\%. Leave-one-out cross-validation confirms generalizability, with cross-validated sensitivity of 72.41\%, specificity of 98.96\%, and F1-score of 76.36\% (95\% confidence intervals reported). A digitization confound analysis demonstrates that the classification is driven by physiological cardiac features rather than data source artifacts. A simulated device acquisition chain analysis confirms that the wearable hardware's signal characteristics are compatible with the classification algorithm. The system offers a promising tool for affordable HCM screening in resource-limited settings.
format Preprint
id arxiv_https___arxiv_org_abs_2604_12934
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle A Wearable ECG Device for Differentiating Hypertrophic Cardiomyopathy from Acquired Left Ventricular Hypertrophy
Li, Jiachen
Zhu, Hanyu
Kim, Edward
Li, Shihao
Cavanaugh, Katherine
Patel, Arpan
De Sirkar, Sovik
Hong, Mauricio
Li, Wei
Chen, Dongmei
Image and Video Processing
Hypertrophic Cardiomyopathy (HCM) is a genetic heart disease affecting approximately 1 in 500 people and is the leading cause of sudden cardiac death in young athletes. Current diagnostic methods -- cardiovascular magnetic resonance (CMR), echocardiography, and genetic testing -- are limited by high costs, operator dependency, or insufficient accuracy, while standard electrocardiogram (ECG) analysis cannot reliably distinguish HCM from acquired left ventricular hypertrophy (LVH). This paper presents a wearable ECG device paired with a classification algorithm that differentiates HCM from acquired LVH using ECG signals alone. The portable device integrates a 3-lead electrode system, an AD8232 signal conditioning module, an Arduino Nano 33 BLE microcontroller, and a lithium polymer battery. The algorithm extracts two quantitative indices -- HCM Index~1 and HCM Index~2 -- from each heartbeat and classifies patients via dual statistical thresholds. Validation on 483 LVH patients (PhysioNet) and 29 HCM patients (digitized clinical records) yields 75.86\% sensitivity, 99.17\% specificity, and an F1-score of 80.00\%. Leave-one-out cross-validation confirms generalizability, with cross-validated sensitivity of 72.41\%, specificity of 98.96\%, and F1-score of 76.36\% (95\% confidence intervals reported). A digitization confound analysis demonstrates that the classification is driven by physiological cardiac features rather than data source artifacts. A simulated device acquisition chain analysis confirms that the wearable hardware's signal characteristics are compatible with the classification algorithm. The system offers a promising tool for affordable HCM screening in resource-limited settings.
title A Wearable ECG Device for Differentiating Hypertrophic Cardiomyopathy from Acquired Left Ventricular Hypertrophy
topic Image and Video Processing
url https://arxiv.org/abs/2604.12934