Saved in:
Bibliographic Details
Main Authors: Zhou, Yeqi, Yao, Songbai, Yu, Jingtian, Qian, Weijia, Wang, Ping, Zhang, Wenwu
Format: Preprint
Published: 2026
Subjects:
Online Access:https://arxiv.org/abs/2604.15401
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910136439668736
author Zhou, Yeqi
Yao, Songbai
Yu, Jingtian
Qian, Weijia
Wang, Ping
Zhang, Wenwu
author_facet Zhou, Yeqi
Yao, Songbai
Yu, Jingtian
Qian, Weijia
Wang, Ping
Zhang, Wenwu
contents This study performs a three-dimensional numerical simulation of the coupled flow field in a hydrogen-air rotating detonation combustor (RDC)-turbine system to evaluate the effectiveness of different film cooling strategies for the turbine blades. The results demonstrate that combining the endwall cooling with leading-edge film cooling effectively reduces blade surface temperatures while improving turbine flow field stability and blade protection. For endwall cooling, numerical simulations compare circular and slot hole configurations. Circular holes consume less cooling air than slot holes while maintaining comparable cooling performance, making them the preferred choice. For the leading-edge film cooling, both the vertical and the vertical-inclined schemes are examined. The vertical-inclined scheme demonstrates higher cooling efficiency and improved secondary flow attachment, ensuring greater stability under the oscillatory effects of the detonation flow. Additionally, the flow fields of film-cooled turbine blades with and without the propagation of the rotating detonation wave are compared, revealing that the upstream rotating detonation flow field facilitates the downstream diffusion of secondary film cooling jets.
format Preprint
id arxiv_https___arxiv_org_abs_2604_15401
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Endwall and leading-edge film cooling of turbine blades in a hydrogen-fueled rotating detonation combustor-turbine coupled system
Zhou, Yeqi
Yao, Songbai
Yu, Jingtian
Qian, Weijia
Wang, Ping
Zhang, Wenwu
Fluid Dynamics
This study performs a three-dimensional numerical simulation of the coupled flow field in a hydrogen-air rotating detonation combustor (RDC)-turbine system to evaluate the effectiveness of different film cooling strategies for the turbine blades. The results demonstrate that combining the endwall cooling with leading-edge film cooling effectively reduces blade surface temperatures while improving turbine flow field stability and blade protection. For endwall cooling, numerical simulations compare circular and slot hole configurations. Circular holes consume less cooling air than slot holes while maintaining comparable cooling performance, making them the preferred choice. For the leading-edge film cooling, both the vertical and the vertical-inclined schemes are examined. The vertical-inclined scheme demonstrates higher cooling efficiency and improved secondary flow attachment, ensuring greater stability under the oscillatory effects of the detonation flow. Additionally, the flow fields of film-cooled turbine blades with and without the propagation of the rotating detonation wave are compared, revealing that the upstream rotating detonation flow field facilitates the downstream diffusion of secondary film cooling jets.
title Endwall and leading-edge film cooling of turbine blades in a hydrogen-fueled rotating detonation combustor-turbine coupled system
topic Fluid Dynamics
url https://arxiv.org/abs/2604.15401