TwinTrack: Post-hoc Multi-Rater Calibration for Medical Image Segmentation

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Kirscher, Tristan, Ertl, Alexandra, Maier-Hein, Klaus, Coubez, Xavier, Meyer, Philippe, Faisan, Sylvain
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866918508785303552
author Kirscher, Tristan
Ertl, Alexandra
Maier-Hein, Klaus
Coubez, Xavier
Meyer, Philippe
Faisan, Sylvain
author_facet Kirscher, Tristan
Ertl, Alexandra
Maier-Hein, Klaus
Coubez, Xavier
Meyer, Philippe
Faisan, Sylvain
contents Pancreatic ductal adenocarcinoma (PDAC) segmentation on contrast-enhanced CT is inherently ambiguous: inter-rater disagreement among experts reflects genuine uncertainty rather than annotation noise. Standard deep learning approaches assume a single ground truth, producing probabilistic outputs that can be poorly calibrated and difficult to interpret under such ambiguity. We present TwinTrack, a framework that addresses this gap through post-hoc calibration of ensemble segmentation probabilities to the empirical mean human response (MHR) -the fraction of expert annotators labeling a voxel as tumor. Calibrated probabilities are thus directly interpretable as the expected proportion of annotators assigning the tumor label, explicitly modeling inter-rater disagreement. The proposed post-hoc calibration procedure is simple and requires only a small multi-rater calibration set. It consistently improves calibration metrics over standard approaches when evaluated on the MICCAI 2025 CURVAS-PDACVI multi-rater benchmark.
format Preprint
id arxiv_https___arxiv_org_abs_2604_15950
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle TwinTrack: Post-hoc Multi-Rater Calibration for Medical Image Segmentation
Kirscher, Tristan
Ertl, Alexandra
Maier-Hein, Klaus
Coubez, Xavier
Meyer, Philippe
Faisan, Sylvain
Machine Learning
Pancreatic ductal adenocarcinoma (PDAC) segmentation on contrast-enhanced CT is inherently ambiguous: inter-rater disagreement among experts reflects genuine uncertainty rather than annotation noise. Standard deep learning approaches assume a single ground truth, producing probabilistic outputs that can be poorly calibrated and difficult to interpret under such ambiguity. We present TwinTrack, a framework that addresses this gap through post-hoc calibration of ensemble segmentation probabilities to the empirical mean human response (MHR) -the fraction of expert annotators labeling a voxel as tumor. Calibrated probabilities are thus directly interpretable as the expected proportion of annotators assigning the tumor label, explicitly modeling inter-rater disagreement. The proposed post-hoc calibration procedure is simple and requires only a small multi-rater calibration set. It consistently improves calibration metrics over standard approaches when evaluated on the MICCAI 2025 CURVAS-PDACVI multi-rater benchmark.
title TwinTrack: Post-hoc Multi-Rater Calibration for Medical Image Segmentation
topic Machine Learning
url https://arxiv.org/abs/2604.15950