Cavity-mode couplings in axion dark matter searches

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autore principale: Ko, Byeong Rok
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866911604045512704
author Ko, Byeong Rok
author_facet Ko, Byeong Rok
contents Axion dark matter searches use a microwave cavity for the resonant conversion of axions into photons to enhance experimental sensitivity, with the cavity generally configured as a two-port system for both signal pickup and cavity characterization measurements. In this study, we investigated cavity-mode couplings in such a two-port system and examined their impact on axion dark matter search experiments, which typically use one strongly coupled port and one weakly coupled port. We found that, in such a two-port cavity system, the measured coupling strength of one port depends on that of the other; hence, the coupling coefficients appearing in the relation for the unloaded quality factor of the cavity mode can vary substantially with the measured coupling strengths. Meanwhile, the scanning rate, the figure-of-merit for axion dark matter searches, cancels the systematic contribution from the strongly coupled port; hence, the remaining systematic uncertainty arises only from the weakly coupled port and may be negligible, depending on its coupling strength. Nevertheless, we recommend measuring the coupling strength of the weakly coupled port to eliminate this systematic uncertainty and thereby recover any experimental sensitivity that may have been lost, for example by approximately 10\% when the coupling strength of the weakly coupled port is 0.05.
format Preprint
id arxiv_https___arxiv_org_abs_2604_16891
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Cavity-mode couplings in axion dark matter searches
Ko, Byeong Rok
High Energy Physics - Phenomenology
High Energy Physics - Experiment
Axion dark matter searches use a microwave cavity for the resonant conversion of axions into photons to enhance experimental sensitivity, with the cavity generally configured as a two-port system for both signal pickup and cavity characterization measurements. In this study, we investigated cavity-mode couplings in such a two-port system and examined their impact on axion dark matter search experiments, which typically use one strongly coupled port and one weakly coupled port. We found that, in such a two-port cavity system, the measured coupling strength of one port depends on that of the other; hence, the coupling coefficients appearing in the relation for the unloaded quality factor of the cavity mode can vary substantially with the measured coupling strengths. Meanwhile, the scanning rate, the figure-of-merit for axion dark matter searches, cancels the systematic contribution from the strongly coupled port; hence, the remaining systematic uncertainty arises only from the weakly coupled port and may be negligible, depending on its coupling strength. Nevertheless, we recommend measuring the coupling strength of the weakly coupled port to eliminate this systematic uncertainty and thereby recover any experimental sensitivity that may have been lost, for example by approximately 10\% when the coupling strength of the weakly coupled port is 0.05.
title Cavity-mode couplings in axion dark matter searches
topic High Energy Physics - Phenomenology
High Energy Physics - Experiment
url https://arxiv.org/abs/2604.16891