Line-scanning Brillouin microscopy with multiplexed two-stage VIPA spectrometer

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Shi, Chenjun, Zhang, Jitao
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866917418081714176
author Shi, Chenjun
Zhang, Jitao
author_facet Shi, Chenjun
Zhang, Jitao
contents Confocal Brillouin microscopy enables high-resolution mechanical imaging but has low acquisition speed, partly due to its pixel-by-pixel mapping strategy. Line-scanning Brillouin microscopy (LSBM) significantly improves imaging speed by utilizing a multiplexing approach. However, current method is limited to a single-stage virtually imaged phased array (VIPA) spectrometer with insufficient capability of suppressing noise. Consequently, an absorptive gas chamber is often used to help reject excessive elastically scattered light. This approach requires specific tunable laser sources whose frequencies (e.g., around 780 nm) are locked to the absorption line of the gas chamber. Here, we developed a multiplexed Brillouin spectrometer for LSBM that increased the noise suppression to 57 dB without using any gas chamber. This is achieved by cascading two VIPA etalons with parallel dispersion axes in the spectrometer, where the first VIPA acts as a band-pass filter and the second as spectrum analyzer. We demonstrated its performance by acquiring Brillouin images of bio-printed phantoms with an inverted co-axial LSBM. This gas-chamber-free approach can expand the implementation of LSBM to other wavelengths where Brillouin scattering is more efficient and commercial laser sources are readily available.
format Preprint
id arxiv_https___arxiv_org_abs_2604_17101
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Line-scanning Brillouin microscopy with multiplexed two-stage VIPA spectrometer
Shi, Chenjun
Zhang, Jitao
Optics
Confocal Brillouin microscopy enables high-resolution mechanical imaging but has low acquisition speed, partly due to its pixel-by-pixel mapping strategy. Line-scanning Brillouin microscopy (LSBM) significantly improves imaging speed by utilizing a multiplexing approach. However, current method is limited to a single-stage virtually imaged phased array (VIPA) spectrometer with insufficient capability of suppressing noise. Consequently, an absorptive gas chamber is often used to help reject excessive elastically scattered light. This approach requires specific tunable laser sources whose frequencies (e.g., around 780 nm) are locked to the absorption line of the gas chamber. Here, we developed a multiplexed Brillouin spectrometer for LSBM that increased the noise suppression to 57 dB without using any gas chamber. This is achieved by cascading two VIPA etalons with parallel dispersion axes in the spectrometer, where the first VIPA acts as a band-pass filter and the second as spectrum analyzer. We demonstrated its performance by acquiring Brillouin images of bio-printed phantoms with an inverted co-axial LSBM. This gas-chamber-free approach can expand the implementation of LSBM to other wavelengths where Brillouin scattering is more efficient and commercial laser sources are readily available.
title Line-scanning Brillouin microscopy with multiplexed two-stage VIPA spectrometer
topic Optics
url https://arxiv.org/abs/2604.17101