Beyond Semantic Similarity: A Component-Wise Evaluation Framework for Medical Question Answering Systems with Health Equity Implications

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sakib, Abu Noman Md, Chisty, Md. Main Oddin, Zhang, Zijie
Format: Preprint
Veröffentlicht: 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866915947287150592
author Sakib, Abu Noman Md
Chisty, Md. Main Oddin
Zhang, Zijie
author_facet Sakib, Abu Noman Md
Chisty, Md. Main Oddin
Zhang, Zijie
contents The use of Large Language Models (LLMs) to support patients in addressing medical questions is becoming increasingly prevalent. However, most of the measures currently used to evaluate the performance of these models in this context only measure how closely a model's answers match semantically, and therefore do not provide a true indication of the model's medical accuracy or of the health equity risks associated with it. To address these shortcomings, we present a new evaluation framework for medical question answering called VB-Score (Verification-Based Score) that provides a separate evaluation of the four components of entity recognition, semantic similarity, factual consistency, and structured information completeness for medical question-answering models. We perform rigorous reviews of the performance of three well-known and widely used LLMs on 48 public health-related topics taken from high-quality, authoritative information sources. Based on our analyses, we discover a major discrepancy between the models' semantic and entity accuracy. Our assessments of the performance of all three models show that each of them has almost uniformly severe performance failures when evaluated against our criteria. Our findings indicate alarming performance disparities across various public health topics, with most of the models exhibiting 13.8% lower performance (compared to an overall average) for all the public health topics that relate to chronic conditions that occur in older and minority populations, which indicates the existence of what's known as condition-based algorithmic discrimination. Our findings also demonstrate that prompt engineering alone does not compensate for basic architectural limitations on how these models perform in extracting medical entities and raise the question of whether semantic evaluation alone is a sufficient measure of medical AI safety.
format Preprint
id arxiv_https___arxiv_org_abs_2604_19281
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Beyond Semantic Similarity: A Component-Wise Evaluation Framework for Medical Question Answering Systems with Health Equity Implications
Sakib, Abu Noman Md
Chisty, Md. Main Oddin
Zhang, Zijie
Human-Computer Interaction
Artificial Intelligence
Computation and Language
Machine Learning
The use of Large Language Models (LLMs) to support patients in addressing medical questions is becoming increasingly prevalent. However, most of the measures currently used to evaluate the performance of these models in this context only measure how closely a model's answers match semantically, and therefore do not provide a true indication of the model's medical accuracy or of the health equity risks associated with it. To address these shortcomings, we present a new evaluation framework for medical question answering called VB-Score (Verification-Based Score) that provides a separate evaluation of the four components of entity recognition, semantic similarity, factual consistency, and structured information completeness for medical question-answering models. We perform rigorous reviews of the performance of three well-known and widely used LLMs on 48 public health-related topics taken from high-quality, authoritative information sources. Based on our analyses, we discover a major discrepancy between the models' semantic and entity accuracy. Our assessments of the performance of all three models show that each of them has almost uniformly severe performance failures when evaluated against our criteria. Our findings indicate alarming performance disparities across various public health topics, with most of the models exhibiting 13.8% lower performance (compared to an overall average) for all the public health topics that relate to chronic conditions that occur in older and minority populations, which indicates the existence of what's known as condition-based algorithmic discrimination. Our findings also demonstrate that prompt engineering alone does not compensate for basic architectural limitations on how these models perform in extracting medical entities and raise the question of whether semantic evaluation alone is a sufficient measure of medical AI safety.
title Beyond Semantic Similarity: A Component-Wise Evaluation Framework for Medical Question Answering Systems with Health Equity Implications
topic Human-Computer Interaction
Artificial Intelligence
Computation and Language
Machine Learning
url https://arxiv.org/abs/2604.19281