Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Li, Zhaochen, Yan, Xinghao, Zhou, Runni, Li, Xiaoyang, Zhu, Chenjie, Wang, Gege, Shi, Yu, Zhang, Lixin, Fu, Rongrong, Yan, Liehao, Chai, Yuan
Format: Preprint
Veröffentlicht: 2026
Schlagworte:
Online-Zugang:https://arxiv.org/abs/2604.20268
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866917427880656896
author Li, Zhaochen
Yan, Xinghao
Zhou, Runni
Li, Xiaoyang
Zhu, Chenjie
Wang, Gege
Shi, Yu
Zhang, Lixin
Fu, Rongrong
Yan, Liehao
Chai, Yuan
author_facet Li, Zhaochen
Yan, Xinghao
Zhou, Runni
Li, Xiaoyang
Zhu, Chenjie
Wang, Gege
Shi, Yu
Zhang, Lixin
Fu, Rongrong
Yan, Liehao
Chai, Yuan
contents Background: Osteoporosis and osteopenia are often undiagnosed until fragility fractures occur. Dual-energy X-ray absorptiometry (DXA) is the reference standard for bone mineral density (BMD) assessment, but access remains limited. Knee radiographs are obtained at high volume for osteoarthritis evaluation and may offer an opportunity for opportunistic bone-loss screening. Objective: To develop and evaluate a multi-task deep learning system for opportunistic bone-loss screening from routine knee radiographs without additional imaging or patient visits. Methods: We developed STR-Net, a multi-task framework for single-channel grayscale knee radiographs. The model includes a shared backbone, global average pooling feature aggregation, a shared neck, and a task-aware representation routing module connected to three task-specific heads: binary screening (Normal vs. Bone Loss), severity sub-classification (Osteopenia vs. Osteoporosis), and weakly coupled T-score regression with optional clinical variables. A sensitivity-constrained threshold optimization strategy (minimum sensitivity >= 0.86) was applied. The dataset included 1,570 knee radiographs, split at the patient level into training (n=1,120), validation (n=226), and test (n=224) sets. Results: On the held-out test set, STR-Net achieved an AUROC of 0.933, sensitivity of 0.904, specificity of 0.773, and AUPRC of 0.956 for binary screening. Severity sub-classification achieved an AUROC of 0.898. The T-score regression branch showed a Pearson correlation of 0.801 with DXA-measured T-scores in a pilot subset (n=31), with MAE of 0.279 and RMSE of 0.347. Conclusions: STR-Net enables single-pass bone-loss screening, severity stratification, and quantitative T-score estimation from routine knee radiographs. Prospective clinical validation is needed before deployment.
format Preprint
id arxiv_https___arxiv_org_abs_2604_20268
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Opportunistic Bone-Loss Screening from Routine Knee Radiographs Using a Multi-Task Deep Learning Framework with Sensitivity-Constrained Threshold Optimization
Li, Zhaochen
Yan, Xinghao
Zhou, Runni
Li, Xiaoyang
Zhu, Chenjie
Wang, Gege
Shi, Yu
Zhang, Lixin
Fu, Rongrong
Yan, Liehao
Chai, Yuan
Computer Vision and Pattern Recognition
Background: Osteoporosis and osteopenia are often undiagnosed until fragility fractures occur. Dual-energy X-ray absorptiometry (DXA) is the reference standard for bone mineral density (BMD) assessment, but access remains limited. Knee radiographs are obtained at high volume for osteoarthritis evaluation and may offer an opportunity for opportunistic bone-loss screening. Objective: To develop and evaluate a multi-task deep learning system for opportunistic bone-loss screening from routine knee radiographs without additional imaging or patient visits. Methods: We developed STR-Net, a multi-task framework for single-channel grayscale knee radiographs. The model includes a shared backbone, global average pooling feature aggregation, a shared neck, and a task-aware representation routing module connected to three task-specific heads: binary screening (Normal vs. Bone Loss), severity sub-classification (Osteopenia vs. Osteoporosis), and weakly coupled T-score regression with optional clinical variables. A sensitivity-constrained threshold optimization strategy (minimum sensitivity >= 0.86) was applied. The dataset included 1,570 knee radiographs, split at the patient level into training (n=1,120), validation (n=226), and test (n=224) sets. Results: On the held-out test set, STR-Net achieved an AUROC of 0.933, sensitivity of 0.904, specificity of 0.773, and AUPRC of 0.956 for binary screening. Severity sub-classification achieved an AUROC of 0.898. The T-score regression branch showed a Pearson correlation of 0.801 with DXA-measured T-scores in a pilot subset (n=31), with MAE of 0.279 and RMSE of 0.347. Conclusions: STR-Net enables single-pass bone-loss screening, severity stratification, and quantitative T-score estimation from routine knee radiographs. Prospective clinical validation is needed before deployment.
title Opportunistic Bone-Loss Screening from Routine Knee Radiographs Using a Multi-Task Deep Learning Framework with Sensitivity-Constrained Threshold Optimization
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2604.20268