Beam test of a Pb/SciFi prototype for the Barrel Imaging Calorimeter at the Electron-Ion Collider

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Lee, Hyungjun, Lee, Changhui, Ryu, Jaehyeok, An, Geunpil, Bae, Joonsuk, Bae, Yunseul, Bok, Jeongsu, Eo, Yun, Ham, Wooseok, Hong, Yoonha, Jadhav, Manoj, Jang, Seo Yun, Jeong, Jinryong, Jo, Hyon-Suk, Joosten, Sylvester, Kim, Beomkyu, Kim, Bobae, Kim, Chong, Kim, Dongguk, Kim, Minsuk, Kim, Shin Hyung, Ko, Wonjun, Lee, Sehwook, Lim, Sanghoon, Metcalfe, Jessica, Papandreou, Zisis, Park, Sangwoo, Shin, Junseop, Yoo, Hwidong, Żurek, Maria
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866917438642192384
author Lee, Hyungjun
Lee, Changhui
Ryu, Jaehyeok
An, Geunpil
Bae, Joonsuk
Bae, Yunseul
Bok, Jeongsu
Eo, Yun
Ham, Wooseok
Hong, Yoonha
Jadhav, Manoj
Jang, Seo Yun
Jeong, Jinryong
Jo, Hyon-Suk
Joosten, Sylvester
Kim, Beomkyu
Kim, Bobae
Kim, Chong
Kim, Dongguk
Kim, Minsuk
Kim, Shin Hyung
Ko, Wonjun
Lee, Sehwook
Lim, Sanghoon
Metcalfe, Jessica
Papandreou, Zisis
Park, Sangwoo
Shin, Junseop
Yoo, Hwidong
Żurek, Maria
author_facet Lee, Hyungjun
Lee, Changhui
Ryu, Jaehyeok
An, Geunpil
Bae, Joonsuk
Bae, Yunseul
Bok, Jeongsu
Eo, Yun
Ham, Wooseok
Hong, Yoonha
Jadhav, Manoj
Jang, Seo Yun
Jeong, Jinryong
Jo, Hyon-Suk
Joosten, Sylvester
Kim, Beomkyu
Kim, Bobae
Kim, Chong
Kim, Dongguk
Kim, Minsuk
Kim, Shin Hyung
Ko, Wonjun
Lee, Sehwook
Lim, Sanghoon
Metcalfe, Jessica
Papandreou, Zisis
Park, Sangwoo
Shin, Junseop
Yoo, Hwidong
Żurek, Maria
contents A Lead-Scintillating Fiber (Pb/SciFi) prototype for the Barrel Imaging Calorimeter (BIC) at the Electron--Ion Collider (EIC) was tested with electron beams at the CERN PS T10 beam line in August 2024. The prototype consisted of unit modules with a sampling structure of lead sheets and scintillating fibers, corresponding to a total depth of approximately $10.9\,X_{0}$. Beam tests were performed with electron momenta between 0.5 and 3~GeV/$c$ to evaluate the energy and timing performance of the prototype. This study characterizes the performance of a Pb/SciFi prototype and provides input for future beam tests, calibration and readout optimization, and the development of larger-scale prototypes.
format Preprint
id arxiv_https___arxiv_org_abs_2604_22647
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Beam test of a Pb/SciFi prototype for the Barrel Imaging Calorimeter at the Electron-Ion Collider
Lee, Hyungjun
Lee, Changhui
Ryu, Jaehyeok
An, Geunpil
Bae, Joonsuk
Bae, Yunseul
Bok, Jeongsu
Eo, Yun
Ham, Wooseok
Hong, Yoonha
Jadhav, Manoj
Jang, Seo Yun
Jeong, Jinryong
Jo, Hyon-Suk
Joosten, Sylvester
Kim, Beomkyu
Kim, Bobae
Kim, Chong
Kim, Dongguk
Kim, Minsuk
Kim, Shin Hyung
Ko, Wonjun
Lee, Sehwook
Lim, Sanghoon
Metcalfe, Jessica
Papandreou, Zisis
Park, Sangwoo
Shin, Junseop
Yoo, Hwidong
Żurek, Maria
Instrumentation and Detectors
A Lead-Scintillating Fiber (Pb/SciFi) prototype for the Barrel Imaging Calorimeter (BIC) at the Electron--Ion Collider (EIC) was tested with electron beams at the CERN PS T10 beam line in August 2024. The prototype consisted of unit modules with a sampling structure of lead sheets and scintillating fibers, corresponding to a total depth of approximately $10.9\,X_{0}$. Beam tests were performed with electron momenta between 0.5 and 3~GeV/$c$ to evaluate the energy and timing performance of the prototype. This study characterizes the performance of a Pb/SciFi prototype and provides input for future beam tests, calibration and readout optimization, and the development of larger-scale prototypes.
title Beam test of a Pb/SciFi prototype for the Barrel Imaging Calorimeter at the Electron-Ion Collider
topic Instrumentation and Detectors
url https://arxiv.org/abs/2604.22647