Fingertip Micro-Motion as a Source of Respiratory Information During Sleep Using Triaxial Accelerometers

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Lin, Jeanne, Liu, Lily, Wu, Hau-Tieng
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866918466639888384
author Lin, Jeanne
Liu, Lily
Wu, Hau-Tieng
author_facet Lin, Jeanne
Liu, Lily
Wu, Hau-Tieng
contents Objective: Triaxial accelerometers (TAAs) are widely used in homecare medicine. This study investigates whether TAA signals recorded at the fingertip encode respiratory information, particularly instantaneous respiratory rate (IRR) and respiratory effort, during sleep. Method: We propose an antiderivative-based nonlinear transformation to convert TAA signals into a respiratory surrogate, termed TAA-resp. To quantify the embedded respiratory-induced motion, a modern time-frequency analysis tool is applied to derive an index, referred to as the respiratory motion index (RMI). The proposed TAA-resp and RMI are validated on a dataset comprising 39 full-night recordings with simultaneous polysomnography (PSG) and a fingertip TAA measurements. Criteria for labeling TAA-resp signal quality as good, moderate, or poor are established, and expert annotations are obtained. Result: On average, TAA-resp over 22.2% $\pm$ 15.6% of full-night recordings encodes high-quality respiratory information, reaching up to 58.9% in some cases. TAA-resp shows stronger correlation with thoracic and abdominal motion than with airflow, indicating predominant capture of respiratory effort. High-quality TAA-resp offers an accurate IRR estimate with root mean square error $0.027 \pm 0.022$ Hz. RMI is higher for high-quality segments and lower for poor-quality segments, and its distribution aligns with physiology, with higher values during REM, N2, and N3 sleep and in the absence of apnea or hypopnea events. In leave-one-subject-out cross-validation, RMI predicts quality labels with 0.74 sensitivity and 0.75 specificity. Conclusion: Fingertip-mounted TAAs encode meaningful respiratory information. Leveraging this underutilized signal may enhance home-based sleep monitoring in channel-limited settings.
format Preprint
id arxiv_https___arxiv_org_abs_2604_22907
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Fingertip Micro-Motion as a Source of Respiratory Information During Sleep Using Triaxial Accelerometers
Lin, Jeanne
Liu, Lily
Wu, Hau-Tieng
Medical Physics
Methodology
Objective: Triaxial accelerometers (TAAs) are widely used in homecare medicine. This study investigates whether TAA signals recorded at the fingertip encode respiratory information, particularly instantaneous respiratory rate (IRR) and respiratory effort, during sleep. Method: We propose an antiderivative-based nonlinear transformation to convert TAA signals into a respiratory surrogate, termed TAA-resp. To quantify the embedded respiratory-induced motion, a modern time-frequency analysis tool is applied to derive an index, referred to as the respiratory motion index (RMI). The proposed TAA-resp and RMI are validated on a dataset comprising 39 full-night recordings with simultaneous polysomnography (PSG) and a fingertip TAA measurements. Criteria for labeling TAA-resp signal quality as good, moderate, or poor are established, and expert annotations are obtained. Result: On average, TAA-resp over 22.2% $\pm$ 15.6% of full-night recordings encodes high-quality respiratory information, reaching up to 58.9% in some cases. TAA-resp shows stronger correlation with thoracic and abdominal motion than with airflow, indicating predominant capture of respiratory effort. High-quality TAA-resp offers an accurate IRR estimate with root mean square error $0.027 \pm 0.022$ Hz. RMI is higher for high-quality segments and lower for poor-quality segments, and its distribution aligns with physiology, with higher values during REM, N2, and N3 sleep and in the absence of apnea or hypopnea events. In leave-one-subject-out cross-validation, RMI predicts quality labels with 0.74 sensitivity and 0.75 specificity. Conclusion: Fingertip-mounted TAAs encode meaningful respiratory information. Leveraging this underutilized signal may enhance home-based sleep monitoring in channel-limited settings.
title Fingertip Micro-Motion as a Source of Respiratory Information During Sleep Using Triaxial Accelerometers
topic Medical Physics
Methodology
url https://arxiv.org/abs/2604.22907