| contents | Anemia affects over one billion people globally and remains severely under-diagnosed in low-resource regions where laboratory blood tests are inaccessible. This paper presents AnemiaVision, an end-to-end web-based system for non-invasive anemia screening from smartphone photographs of the palpebral conjunctiva and fingernail beds. The proposed pipeline fine-tunes a pre-trained EfficientNet-B3 backbone with a redesigned three-layer classifier head incorporating BatchNorm, GELU activations, and high-rate Dropout (0.45/0.35). Training employs four orthogonal accuracy-boosting techniques: TrivialAugmentWide for policy-free image augmentation, RandomErasing for spatial regularisation, Mixup (alpha=0.2) for inter-class smoothing, and cosine-annealing scheduling with linear warmup. Early stopping is governed by peak validation accuracy rather than validation loss to prevent premature termination on high-variance epochs. The deployed Flask application integrates persistent patient-history management backed by PostgreSQL on Render, with an automated database-migration entrypoint ensuring zero data loss across redeploys. Ablation experiments demonstrate that accuracy-first early stopping contributes +1.6% and Mixup contributes +2.8% to final validation accuracy. Overall, the proposed system achieves a validation accuracy of 96.2% and AUC-ROC of 0.98, compared with 44.9% validation accuracy and AUC-ROC of 0.58 from the three-epoch CPU-only baseline. Sensitivity for the anemic class reaches 0.96, making the system suitable as a first-line screening tool for community health workers in rural settings. The system is publicly accessible and source code is openly available. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2604_22964 |
| institution | arXiv |
| publishDate | 2026 |
| record_format | arxiv |
| spellingShingle | AnemiaVision: Non-Invasive Anemia Detection via Smartphone Imagery Using EfficientNet-B3 with TrivialAugmentWide, Mixup Augmentation, and Persistent Patient History Management Patel, Rahul Computer Vision and Pattern Recognition Machine Learning Software Engineering I.2.10; I.4.9; J.3 Anemia affects over one billion people globally and remains severely under-diagnosed in low-resource regions where laboratory blood tests are inaccessible. This paper presents AnemiaVision, an end-to-end web-based system for non-invasive anemia screening from smartphone photographs of the palpebral conjunctiva and fingernail beds. The proposed pipeline fine-tunes a pre-trained EfficientNet-B3 backbone with a redesigned three-layer classifier head incorporating BatchNorm, GELU activations, and high-rate Dropout (0.45/0.35). Training employs four orthogonal accuracy-boosting techniques: TrivialAugmentWide for policy-free image augmentation, RandomErasing for spatial regularisation, Mixup (alpha=0.2) for inter-class smoothing, and cosine-annealing scheduling with linear warmup. Early stopping is governed by peak validation accuracy rather than validation loss to prevent premature termination on high-variance epochs. The deployed Flask application integrates persistent patient-history management backed by PostgreSQL on Render, with an automated database-migration entrypoint ensuring zero data loss across redeploys. Ablation experiments demonstrate that accuracy-first early stopping contributes +1.6% and Mixup contributes +2.8% to final validation accuracy. Overall, the proposed system achieves a validation accuracy of 96.2% and AUC-ROC of 0.98, compared with 44.9% validation accuracy and AUC-ROC of 0.58 from the three-epoch CPU-only baseline. Sensitivity for the anemic class reaches 0.96, making the system suitable as a first-line screening tool for community health workers in rural settings. The system is publicly accessible and source code is openly available. |
| title | AnemiaVision: Non-Invasive Anemia Detection via Smartphone Imagery Using EfficientNet-B3 with TrivialAugmentWide, Mixup Augmentation, and Persistent Patient History Management |
| topic | Computer Vision and Pattern Recognition Machine Learning Software Engineering I.2.10; I.4.9; J.3 |
| url | https://arxiv.org/abs/2604.22964 |