Knee-xRAI: An Explainable AI Framework for Automatic Kellgren-Lawrence Grading of Knee Osteoarthritis

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Irfan, Azmul A., Khatim, Nur Ahmad, Irfan, Alfan Alfian, Zaki, Achmad, Suwarsono, Erike A., Arief, Mansur M.
Format: Preprint
Veröffentlicht: 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866913062611582976
author Irfan, Azmul A.
Khatim, Nur Ahmad
Irfan, Alfan Alfian
Zaki, Achmad
Suwarsono, Erike A.
Arief, Mansur M.
author_facet Irfan, Azmul A.
Khatim, Nur Ahmad
Irfan, Alfan Alfian
Zaki, Achmad
Suwarsono, Erike A.
Arief, Mansur M.
contents Radiographic grading of knee osteoarthritis (KOA) with the Kellgren-Lawrence (KL) system is limited by inter-reader variability and the opacity of current deep learning approaches, which predict KL grades directly from images without decomposing structural features. We present Knee-xRAI, a modular framework that independently quantifies the three cardinal radiographic features of KOA (joint space narrowing [JSN], osteophytes, and subchondral sclerosis) and integrates them into an explainable KL grade classification. The pipeline combines U-Net++ segmentation for contour-based JSN measurement, an SE-ResNet-50 network for per-site osteophyte grading (OARSI scale), and a hybrid texture-CNN classifier for binary sclerosis quantification. The resulting 50-dimensional structured feature vector feeds two complementary classification paths. An XGBoost path supports SHAP-based feature attribution. A ConvNeXt hybrid path combines the structured vector with a full-image encoder for enhanced predictive performance. Evaluated on 8,260 radiographs from an OAI-derived dataset, the JSN module achieved a Dice coefficient of 0.8909 and an mJSW intraclass correlation of 0.8674 against manual annotations. The ConvNeXt hybrid path reached a test quadratic weighted kappa (QWK) of 0.8436 and AUC of 0.9017. The transparent XGBoost path achieved a test QWK of 0.6294 with full feature-level audit capability. Ablation confirmed JSN as the dominant predictor (QWK = 0.6103 alone), with osteophyte features providing consistent incremental gain (+0.0183) and sclerosis contributing marginally. Inference-time ablation of Path B confirmed the structured pathway contributes materially beyond the image encoder, with QWK drops of 0.098 (feature zeroing) and 0.284 (feature-image permutation). Knee-xRAI explicitly quantifies all three KL-defining radiographic features within a single auditable pipeline.
format Preprint
id arxiv_https___arxiv_org_abs_2604_23435
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Knee-xRAI: An Explainable AI Framework for Automatic Kellgren-Lawrence Grading of Knee Osteoarthritis
Irfan, Azmul A.
Khatim, Nur Ahmad
Irfan, Alfan Alfian
Zaki, Achmad
Suwarsono, Erike A.
Arief, Mansur M.
Computer Vision and Pattern Recognition
Artificial Intelligence
Machine Learning
Radiographic grading of knee osteoarthritis (KOA) with the Kellgren-Lawrence (KL) system is limited by inter-reader variability and the opacity of current deep learning approaches, which predict KL grades directly from images without decomposing structural features. We present Knee-xRAI, a modular framework that independently quantifies the three cardinal radiographic features of KOA (joint space narrowing [JSN], osteophytes, and subchondral sclerosis) and integrates them into an explainable KL grade classification. The pipeline combines U-Net++ segmentation for contour-based JSN measurement, an SE-ResNet-50 network for per-site osteophyte grading (OARSI scale), and a hybrid texture-CNN classifier for binary sclerosis quantification. The resulting 50-dimensional structured feature vector feeds two complementary classification paths. An XGBoost path supports SHAP-based feature attribution. A ConvNeXt hybrid path combines the structured vector with a full-image encoder for enhanced predictive performance. Evaluated on 8,260 radiographs from an OAI-derived dataset, the JSN module achieved a Dice coefficient of 0.8909 and an mJSW intraclass correlation of 0.8674 against manual annotations. The ConvNeXt hybrid path reached a test quadratic weighted kappa (QWK) of 0.8436 and AUC of 0.9017. The transparent XGBoost path achieved a test QWK of 0.6294 with full feature-level audit capability. Ablation confirmed JSN as the dominant predictor (QWK = 0.6103 alone), with osteophyte features providing consistent incremental gain (+0.0183) and sclerosis contributing marginally. Inference-time ablation of Path B confirmed the structured pathway contributes materially beyond the image encoder, with QWK drops of 0.098 (feature zeroing) and 0.284 (feature-image permutation). Knee-xRAI explicitly quantifies all three KL-defining radiographic features within a single auditable pipeline.
title Knee-xRAI: An Explainable AI Framework for Automatic Kellgren-Lawrence Grading of Knee Osteoarthritis
topic Computer Vision and Pattern Recognition
Artificial Intelligence
Machine Learning
url https://arxiv.org/abs/2604.23435