Exploring Prompt Alignment with Clinical Factors in Zero-Shot Segmentation VLMs for NSCLC Tumor Segmentation

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Pai, Suraj, Heintz, Thibault, Ciausu, Cosmin, Tonneau, Marion, Aerts, Hugo, Mak, Raymond
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866911640304222208
author Pai, Suraj
Heintz, Thibault
Ciausu, Cosmin
Tonneau, Marion
Aerts, Hugo
Mak, Raymond
author_facet Pai, Suraj
Heintz, Thibault
Ciausu, Cosmin
Tonneau, Marion
Aerts, Hugo
Mak, Raymond
contents Zero-shot vision-language models (VLMs) offer a promptable alternative to task-specific training for gross tumor volume (GTV) delineation in non-small-cell lung cancer (NSCLC), but the prompt dimensions that govern their spatial behavior remain poorly understood. We study this question by probing alignment directions in VoxTell on a held-out internal NSCLC tumor dataset through sub-prompt decomposition into diagnosis, demographic, staging, anatomical, generic, and irrelevant controls; attribute-wise perturbation robustness; specificity ladders; and cross-case prompt swaps, while benchmarking against fine-tuned and zero-shot baselines using the Dice Similarity Coefficient (DSC) with Wilcoxon signed-rank tests and Benjamini-Hochberg correction. Alignment analyses revealed that anatomical location is the dominant driver of VoxTell's spatial attention: 63.4 percent of location perturbations caused catastrophic drops, prompt specificity improved from generic to full descriptions except for diagnosis-only prompts, irrelevant prompts correctly yielded zero segmentation, and cross-case prompt swaps confirmed patient-specific conditioning (matched DSC 0.906 vs. mismatched 0.406). Histology and stage substitutions had minimal effect, indicating that the model prioritizes "where to look" over "what to look for." In this context, VoxTell, operating fully zero-shot, achieved a mean DSC of 0.613, statistically indistinguishable from nnUNet (0.690, adjusted p = 0.156) and Ahmed et al. (0.675, adjusted p = 0.679), while significantly outperforming all other zero-shot models. Together, these findings argue that segmentation VLMs should be evaluated not only by Dice, but also by the prompt dimensions to which they align.
format Preprint
id arxiv_https___arxiv_org_abs_2605_01266
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Exploring Prompt Alignment with Clinical Factors in Zero-Shot Segmentation VLMs for NSCLC Tumor Segmentation
Pai, Suraj
Heintz, Thibault
Ciausu, Cosmin
Tonneau, Marion
Aerts, Hugo
Mak, Raymond
Computer Vision and Pattern Recognition
Zero-shot vision-language models (VLMs) offer a promptable alternative to task-specific training for gross tumor volume (GTV) delineation in non-small-cell lung cancer (NSCLC), but the prompt dimensions that govern their spatial behavior remain poorly understood. We study this question by probing alignment directions in VoxTell on a held-out internal NSCLC tumor dataset through sub-prompt decomposition into diagnosis, demographic, staging, anatomical, generic, and irrelevant controls; attribute-wise perturbation robustness; specificity ladders; and cross-case prompt swaps, while benchmarking against fine-tuned and zero-shot baselines using the Dice Similarity Coefficient (DSC) with Wilcoxon signed-rank tests and Benjamini-Hochberg correction. Alignment analyses revealed that anatomical location is the dominant driver of VoxTell's spatial attention: 63.4 percent of location perturbations caused catastrophic drops, prompt specificity improved from generic to full descriptions except for diagnosis-only prompts, irrelevant prompts correctly yielded zero segmentation, and cross-case prompt swaps confirmed patient-specific conditioning (matched DSC 0.906 vs. mismatched 0.406). Histology and stage substitutions had minimal effect, indicating that the model prioritizes "where to look" over "what to look for." In this context, VoxTell, operating fully zero-shot, achieved a mean DSC of 0.613, statistically indistinguishable from nnUNet (0.690, adjusted p = 0.156) and Ahmed et al. (0.675, adjusted p = 0.679), while significantly outperforming all other zero-shot models. Together, these findings argue that segmentation VLMs should be evaluated not only by Dice, but also by the prompt dimensions to which they align.
title Exploring Prompt Alignment with Clinical Factors in Zero-Shot Segmentation VLMs for NSCLC Tumor Segmentation
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2605.01266