Charging-up and reverse charging-up phenomena in a double-mask triple GEM detector

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Mandal, S., Ghosh, S., Das, S., Biswas, S.
Format: Preprint
Veröffentlicht: 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866918482252136448
author Mandal, S.
Ghosh, S.
Das, S.
Biswas, S.
author_facet Mandal, S.
Ghosh, S.
Das, S.
Biswas, S.
contents The Gas Electron Multiplier (GEM) detectors are widely used in high-energy physics (HEP) experiments as tracking devices because of their excellent position resolution and to handle high particle rates capability. Charging-up effect is a well known phenomenon in GEM detectors because of the presence of the dielectric medium -- Kapton in the foil. Charging-up of GEM foil takes place when it is exposed to high radiation after application of high voltage. A new phenomenon of reverse charging-up, a complementary behaviour is also observed when the irradiation rate is reduced, where the gain relaxes gradually towards its initial value. In this study, the charging-up and reverse charging-up effects are investigated for a double-mask triple GEM chamber operated with an Argon and Carbon dioxide (70/30) gas mixture. The measurements provide a detailed understanding of the gain variation under irradiation and its stabilisation behaviour. The experimental setup, methodology and results are presented in this article.
format Preprint
id arxiv_https___arxiv_org_abs_2605_02922
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Charging-up and reverse charging-up phenomena in a double-mask triple GEM detector
Mandal, S.
Ghosh, S.
Das, S.
Biswas, S.
Instrumentation and Detectors
High Energy Physics - Experiment
The Gas Electron Multiplier (GEM) detectors are widely used in high-energy physics (HEP) experiments as tracking devices because of their excellent position resolution and to handle high particle rates capability. Charging-up effect is a well known phenomenon in GEM detectors because of the presence of the dielectric medium -- Kapton in the foil. Charging-up of GEM foil takes place when it is exposed to high radiation after application of high voltage. A new phenomenon of reverse charging-up, a complementary behaviour is also observed when the irradiation rate is reduced, where the gain relaxes gradually towards its initial value. In this study, the charging-up and reverse charging-up effects are investigated for a double-mask triple GEM chamber operated with an Argon and Carbon dioxide (70/30) gas mixture. The measurements provide a detailed understanding of the gain variation under irradiation and its stabilisation behaviour. The experimental setup, methodology and results are presented in this article.
title Charging-up and reverse charging-up phenomena in a double-mask triple GEM detector
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2605.02922