Study of Particle Fluence Effects on Collected Charge and Depletion Voltage of the ATLAS IBL Planar Pixel Sensors

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: ATLAS Collaboration
Format: Preprint
Veröffentlicht: 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866918486206316544
author ATLAS Collaboration
author_facet ATLAS Collaboration
contents After ten years of operation at the LHC, the planar pixel sensors of the innermost barrel layer of the ATLAS Pixel detector have accumulated an average bulk damage fluence in excess of $2\times10^{15}$ 1 MeV-neutrons equivalent/cm$^2$. The macroscopic effects of this radiation are an increase of the sensor leakage current, a loss of charge collection efficiency and an increase of the depletion voltage. Using regular bias voltage scans performed at the beginning and end of each data taking campaign the evolution of the pixel cluster charge and bulk depletion is studied as a function of particle fluence. Results are interpreted with the modelling provided by standalone TCAD and ATLAS Monte Carlo simulation including radiation damage effects. The dependence of the collected charge and the depletion voltage with integrated luminosity are studied through the full period of operation.
format Preprint
id arxiv_https___arxiv_org_abs_2605_05030
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Study of Particle Fluence Effects on Collected Charge and Depletion Voltage of the ATLAS IBL Planar Pixel Sensors
ATLAS Collaboration
Instrumentation and Detectors
High Energy Physics - Experiment
After ten years of operation at the LHC, the planar pixel sensors of the innermost barrel layer of the ATLAS Pixel detector have accumulated an average bulk damage fluence in excess of $2\times10^{15}$ 1 MeV-neutrons equivalent/cm$^2$. The macroscopic effects of this radiation are an increase of the sensor leakage current, a loss of charge collection efficiency and an increase of the depletion voltage. Using regular bias voltage scans performed at the beginning and end of each data taking campaign the evolution of the pixel cluster charge and bulk depletion is studied as a function of particle fluence. Results are interpreted with the modelling provided by standalone TCAD and ATLAS Monte Carlo simulation including radiation damage effects. The dependence of the collected charge and the depletion voltage with integrated luminosity are studied through the full period of operation.
title Study of Particle Fluence Effects on Collected Charge and Depletion Voltage of the ATLAS IBL Planar Pixel Sensors
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2605.05030