Study of Particle Fluence Effects on Collected Charge and Depletion Voltage of the ATLAS IBL Planar Pixel Sensors
Fuente:
arXiv
Gespeichert in:
| 1. Verfasser: | |
|---|---|
| Format: | Preprint |
| Veröffentlicht: |
2026
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1866918486206316544 |
|---|---|
| author | ATLAS Collaboration |
| author_facet | ATLAS Collaboration |
| contents | After ten years of operation at the LHC, the planar pixel sensors of the innermost barrel layer of the ATLAS Pixel detector have accumulated an average bulk damage fluence in excess of $2\times10^{15}$ 1 MeV-neutrons equivalent/cm$^2$. The macroscopic effects of this radiation are an increase of the sensor leakage current, a loss of charge collection efficiency and an increase of the depletion voltage. Using regular bias voltage scans performed at the beginning and end of each data taking campaign the evolution of the pixel cluster charge and bulk depletion is studied as a function of particle fluence. Results are interpreted with the modelling provided by standalone TCAD and ATLAS Monte Carlo simulation including radiation damage effects. The dependence of the collected charge and the depletion voltage with integrated luminosity are studied through the full period of operation. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2605_05030 |
| institution | arXiv |
| publishDate | 2026 |
| record_format | arxiv |
| spellingShingle | Study of Particle Fluence Effects on Collected Charge and Depletion Voltage of the ATLAS IBL Planar Pixel Sensors ATLAS Collaboration Instrumentation and Detectors High Energy Physics - Experiment After ten years of operation at the LHC, the planar pixel sensors of the innermost barrel layer of the ATLAS Pixel detector have accumulated an average bulk damage fluence in excess of $2\times10^{15}$ 1 MeV-neutrons equivalent/cm$^2$. The macroscopic effects of this radiation are an increase of the sensor leakage current, a loss of charge collection efficiency and an increase of the depletion voltage. Using regular bias voltage scans performed at the beginning and end of each data taking campaign the evolution of the pixel cluster charge and bulk depletion is studied as a function of particle fluence. Results are interpreted with the modelling provided by standalone TCAD and ATLAS Monte Carlo simulation including radiation damage effects. The dependence of the collected charge and the depletion voltage with integrated luminosity are studied through the full period of operation. |
| title | Study of Particle Fluence Effects on Collected Charge and Depletion Voltage of the ATLAS IBL Planar Pixel Sensors |
| topic | Instrumentation and Detectors High Energy Physics - Experiment |
| url | https://arxiv.org/abs/2605.05030 |