Development of a Proton Therapy Research Beamline with FLASH and Minibeam Capabilities at the 18 MeV Bern Medical Cyclotron

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Kasanda, Eva, Eggiman, Lars, Stammbach, Thierry, Casolaro, Pierluigi, Dellepiane, Gaia, Gottstein, Alexander, Gruber, Jan, Mateu, Isidre, Pellicioli, Paolo, Rossi, Maria Vittoria, Scampoli, Paola, Palomo, Cristian Fernandez, Braccini, Saverio
Formato: Preprint
Publicado: 2026
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866911699592806400
author Kasanda, Eva
Eggiman, Lars
Stammbach, Thierry
Casolaro, Pierluigi
Dellepiane, Gaia
Gottstein, Alexander
Gruber, Jan
Mateu, Isidre
Pellicioli, Paolo
Rossi, Maria Vittoria
Scampoli, Paola
Palomo, Cristian Fernandez
Braccini, Saverio
author_facet Kasanda, Eva
Eggiman, Lars
Stammbach, Thierry
Casolaro, Pierluigi
Dellepiane, Gaia
Gottstein, Alexander
Gruber, Jan
Mateu, Isidre
Pellicioli, Paolo
Rossi, Maria Vittoria
Scampoli, Paola
Palomo, Cristian Fernandez
Braccini, Saverio
contents Advanced radiotherapy approaches such as FLASH irradiation and spatially fractionated radiotherapy (SFRT) show potential to improve the therapeutic ratio, yet their biological mechanisms and optimal delivery parameters remain uncertain. Progress requires accessible proton research platforms with flexible temporal and spatial dose delivery. We report on the adaptation of the Beam Transfer Line (BTL) of the Bern Medical Cyclotron (BMC) for radiobiology research with FLASH and proton minibeam capabilities. The BMC is optimized for the production of radionuclides for medical imaging, and is able to extract currents up to 150 $ \mathrm{μA}$. The 18 MeV proton beam was passively shaped using collimators, scattering foils, and extended drift space to generate irradiation fields. A dosimetric framework was implemented using an in-beam ionization chamber and radiochromic film with LET-dependent corrections. Beam uniformity and SFRT profiles with various grid spacings were evaluated at realistic target distances. The developed beamline enables stable delivery under controlled conditions in both conventional and FLASH regimes, spanning dose rates from 0.01 to 100 Gy/s. Dose uniformity within a 20 mm radius was below 8\%. Film measurements confirmed the need for LET-dependent corrections and indicated that quantitative dosimetry in in-vitro setups is achievable with appropriate LET corrections. The low proton energy (15.54(12) MeV extracted into air, 8.14(28) MeV delivered to cells in flask) facilitates compact SFRT implementation with well-resolved minibeams. The adapted BMC provides a flexible and accessible platform for systematic pre-clinical proton radiobiology studies under varied dose-rate and spatial delivery conditions. This supports optimization of emerging modalities such as proton FLASH and SFRT and helps bridge accelerator technology and radiobiology.
format Preprint
id arxiv_https___arxiv_org_abs_2605_05441
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Development of a Proton Therapy Research Beamline with FLASH and Minibeam Capabilities at the 18 MeV Bern Medical Cyclotron
Kasanda, Eva
Eggiman, Lars
Stammbach, Thierry
Casolaro, Pierluigi
Dellepiane, Gaia
Gottstein, Alexander
Gruber, Jan
Mateu, Isidre
Pellicioli, Paolo
Rossi, Maria Vittoria
Scampoli, Paola
Palomo, Cristian Fernandez
Braccini, Saverio
Medical Physics
Accelerator Physics
Instrumentation and Detectors
Advanced radiotherapy approaches such as FLASH irradiation and spatially fractionated radiotherapy (SFRT) show potential to improve the therapeutic ratio, yet their biological mechanisms and optimal delivery parameters remain uncertain. Progress requires accessible proton research platforms with flexible temporal and spatial dose delivery. We report on the adaptation of the Beam Transfer Line (BTL) of the Bern Medical Cyclotron (BMC) for radiobiology research with FLASH and proton minibeam capabilities. The BMC is optimized for the production of radionuclides for medical imaging, and is able to extract currents up to 150 $ \mathrm{μA}$. The 18 MeV proton beam was passively shaped using collimators, scattering foils, and extended drift space to generate irradiation fields. A dosimetric framework was implemented using an in-beam ionization chamber and radiochromic film with LET-dependent corrections. Beam uniformity and SFRT profiles with various grid spacings were evaluated at realistic target distances. The developed beamline enables stable delivery under controlled conditions in both conventional and FLASH regimes, spanning dose rates from 0.01 to 100 Gy/s. Dose uniformity within a 20 mm radius was below 8\%. Film measurements confirmed the need for LET-dependent corrections and indicated that quantitative dosimetry in in-vitro setups is achievable with appropriate LET corrections. The low proton energy (15.54(12) MeV extracted into air, 8.14(28) MeV delivered to cells in flask) facilitates compact SFRT implementation with well-resolved minibeams. The adapted BMC provides a flexible and accessible platform for systematic pre-clinical proton radiobiology studies under varied dose-rate and spatial delivery conditions. This supports optimization of emerging modalities such as proton FLASH and SFRT and helps bridge accelerator technology and radiobiology.
title Development of a Proton Therapy Research Beamline with FLASH and Minibeam Capabilities at the 18 MeV Bern Medical Cyclotron
topic Medical Physics
Accelerator Physics
Instrumentation and Detectors
url https://arxiv.org/abs/2605.05441