Clinical Utility and Feasibility of Smartphone-based EEG in Kenya: A Multicenter Observational Study

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Enkhtsetseg, Nomin, Lehn-Schiøler, William, Storgaard, Anton Mosquera, Pedersen, Magnus Guldberg, Rice, Dylan, Wambugu, George, Fidele, Nshimiyimana Jules, Hribljan, Melita Cacic, Arbune, Anca Alina, Larsen, Sidsel Armand, Beniczky, Sandor, Mateen, Farrah J.
Formato: Preprint
Publicado: 2026
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866913139690307584
author Enkhtsetseg, Nomin
Lehn-Schiøler, William
Storgaard, Anton Mosquera
Pedersen, Magnus Guldberg
Rice, Dylan
Wambugu, George
Fidele, Nshimiyimana Jules
Hribljan, Melita Cacic
Arbune, Anca Alina
Larsen, Sidsel Armand
Beniczky, Sandor
Mateen, Farrah J.
author_facet Enkhtsetseg, Nomin
Lehn-Schiøler, William
Storgaard, Anton Mosquera
Pedersen, Magnus Guldberg
Rice, Dylan
Wambugu, George
Fidele, Nshimiyimana Jules
Hribljan, Melita Cacic
Arbune, Anca Alina
Larsen, Sidsel Armand
Beniczky, Sandor
Mateen, Farrah J.
contents Purpose: Access to electroencephalography (EEG) remains limited across low- and middle-income countries (LMICs) due to cost, infrastructure requirements, and a shortage of trained staff. This study evaluated the feasibility and clinical utility of a smartphone-based EEG system in a real-world setting. Methods: We conducted a multicenter observational study (November 2023 to April 2026) across 29 clinical sites in Kenya. A smartphone-based 27-lead EEG system enabled trained healthcare workers to acquire standardized recordings with remote expert interpretation. Results: 3,036 EEG sessions were performed. Male patients constituted 57.8% of the cohort, with representation across pediatric and adult populations. The most common referral indication was seizures or convulsions (68.5%). Overall, 2,915 (96%) recordings were interpretable, while 121 (4%) were uninterpretable, primarily due to high electrode impedance and insufficient recording duration. Uninterpretable recordings were significantly shorter than interpretable recordings (mean 18.5 vs. 33.8 minutes; median 15.1 vs. 31.6 minutes; p < 0.0001). Mean turnaround time for interpretation was 107 minutes. Among interpretable recordings, 917 (30.2%) were abnormal, including 701 (76.4%) with epileptiform abnormalities, 215 (23.4%) with non-epileptiform findings, and 1 (0.1%) indeterminate finding. Epileptiform abnormalities were highest in children aged 4-9 years (33.1%) and less frequent in adults (14-21%). Non-epileptiform abnormalities were more common in patients aged 60+ years (19.2%) compared to younger age groups (3-9%). Conclusion: Large-scale, point-of-care EEG acquisition by non-specialist operators in a resource-limited setting is feasible. Expansion of smartphone-based EEG systems may improve equitable access to neurological diagnosis and care in LMICs.
format Preprint
id arxiv_https___arxiv_org_abs_2605_08157
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Clinical Utility and Feasibility of Smartphone-based EEG in Kenya: A Multicenter Observational Study
Enkhtsetseg, Nomin
Lehn-Schiøler, William
Storgaard, Anton Mosquera
Pedersen, Magnus Guldberg
Rice, Dylan
Wambugu, George
Fidele, Nshimiyimana Jules
Hribljan, Melita Cacic
Arbune, Anca Alina
Larsen, Sidsel Armand
Beniczky, Sandor
Mateen, Farrah J.
Signal Processing
Computers and Society
Purpose: Access to electroencephalography (EEG) remains limited across low- and middle-income countries (LMICs) due to cost, infrastructure requirements, and a shortage of trained staff. This study evaluated the feasibility and clinical utility of a smartphone-based EEG system in a real-world setting. Methods: We conducted a multicenter observational study (November 2023 to April 2026) across 29 clinical sites in Kenya. A smartphone-based 27-lead EEG system enabled trained healthcare workers to acquire standardized recordings with remote expert interpretation. Results: 3,036 EEG sessions were performed. Male patients constituted 57.8% of the cohort, with representation across pediatric and adult populations. The most common referral indication was seizures or convulsions (68.5%). Overall, 2,915 (96%) recordings were interpretable, while 121 (4%) were uninterpretable, primarily due to high electrode impedance and insufficient recording duration. Uninterpretable recordings were significantly shorter than interpretable recordings (mean 18.5 vs. 33.8 minutes; median 15.1 vs. 31.6 minutes; p < 0.0001). Mean turnaround time for interpretation was 107 minutes. Among interpretable recordings, 917 (30.2%) were abnormal, including 701 (76.4%) with epileptiform abnormalities, 215 (23.4%) with non-epileptiform findings, and 1 (0.1%) indeterminate finding. Epileptiform abnormalities were highest in children aged 4-9 years (33.1%) and less frequent in adults (14-21%). Non-epileptiform abnormalities were more common in patients aged 60+ years (19.2%) compared to younger age groups (3-9%). Conclusion: Large-scale, point-of-care EEG acquisition by non-specialist operators in a resource-limited setting is feasible. Expansion of smartphone-based EEG systems may improve equitable access to neurological diagnosis and care in LMICs.
title Clinical Utility and Feasibility of Smartphone-based EEG in Kenya: A Multicenter Observational Study
topic Signal Processing
Computers and Society
url https://arxiv.org/abs/2605.08157