Development and validation of a forward 0.7--4 MeV quasi-monoenergetic neutron capability at the CN Van de Graaff of LNL

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Wyss, Jeffery, Mastinu, Pierfrancesco, González, Elizabeth Musacchio, Hernández, Guido Martín, Silvestrin, Luca, Monetti, Alberto, Steiger, Hans Th. J., Böhles, Manuel, Lalremruata, B., Alberton, Saulo Gabriel, Flechas, David
Formato: Preprint
Publicado: 2026
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866910212129030144
author Wyss, Jeffery
Mastinu, Pierfrancesco
González, Elizabeth Musacchio
Hernández, Guido Martín
Silvestrin, Luca
Monetti, Alberto
Steiger, Hans Th. J.
Böhles, Manuel
Lalremruata, B.
Alberton, Saulo Gabriel
Flechas, David
author_facet Wyss, Jeffery
Mastinu, Pierfrancesco
González, Elizabeth Musacchio
Hernández, Guido Martín
Silvestrin, Luca
Monetti, Alberto
Steiger, Hans Th. J.
Böhles, Manuel
Lalremruata, B.
Alberton, Saulo Gabriel
Flechas, David
contents The CN Van de Graaff accelerator of INFN--LNL provides forward-angle quasi-monoenergetic neutrons in the 0.7--4 MeV range via the 7Li(p,n)7Be reaction on thin metallic lithium targets. This work describes the development and experimental validation of this forward neutron capability, combining comparisons of commonly used transport tools with time-of-flight (ToF) measurements. Neutron yields calculated with EPEN, FLUKA, MCNPX, and PINO are compared over the CN energy range in order to assess model-dependent variations relevant for fluence estimates. For zero incident-energy spread, a mutually consistent set of transport calculations agrees within 5% and is used as a practical reference for normalisation. The effect of incident-energy convolution on the predicted yields is examined. Time-of-flight measurements performed using a sub-nanosecond secondary pulsing system verify the timing structure and forward-angle kinematics of the quasi-monoenergetic neutron component at the detector position, with neutron arrival times consistent with the expected forward kinematics within the experimental resolution. Using measured proton currents and transport calculations based on this reference set, forward neutron fluences at the device position are estimated with an overall uncertainty of approximately 9%, including contributions from current integration, target thickness, and geometry. A short device irradiation, carried out in parallel with the ToF campaign, demonstrates measurable response under CN beam conditions and confirms the practical usability of the beam for low-MeV neutron studies. Together, these results establish the current operational performance of the CN 0° forward quasi-monoenergetic neutron capability in the 0.7--4 MeV range and identify the steps required toward routine calibrated operation.
format Preprint
id arxiv_https___arxiv_org_abs_2605_12005
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Development and validation of a forward 0.7--4 MeV quasi-monoenergetic neutron capability at the CN Van de Graaff of LNL
Wyss, Jeffery
Mastinu, Pierfrancesco
González, Elizabeth Musacchio
Hernández, Guido Martín
Silvestrin, Luca
Monetti, Alberto
Steiger, Hans Th. J.
Böhles, Manuel
Lalremruata, B.
Alberton, Saulo Gabriel
Flechas, David
Instrumentation and Detectors
The CN Van de Graaff accelerator of INFN--LNL provides forward-angle quasi-monoenergetic neutrons in the 0.7--4 MeV range via the 7Li(p,n)7Be reaction on thin metallic lithium targets. This work describes the development and experimental validation of this forward neutron capability, combining comparisons of commonly used transport tools with time-of-flight (ToF) measurements. Neutron yields calculated with EPEN, FLUKA, MCNPX, and PINO are compared over the CN energy range in order to assess model-dependent variations relevant for fluence estimates. For zero incident-energy spread, a mutually consistent set of transport calculations agrees within 5% and is used as a practical reference for normalisation. The effect of incident-energy convolution on the predicted yields is examined. Time-of-flight measurements performed using a sub-nanosecond secondary pulsing system verify the timing structure and forward-angle kinematics of the quasi-monoenergetic neutron component at the detector position, with neutron arrival times consistent with the expected forward kinematics within the experimental resolution. Using measured proton currents and transport calculations based on this reference set, forward neutron fluences at the device position are estimated with an overall uncertainty of approximately 9%, including contributions from current integration, target thickness, and geometry. A short device irradiation, carried out in parallel with the ToF campaign, demonstrates measurable response under CN beam conditions and confirms the practical usability of the beam for low-MeV neutron studies. Together, these results establish the current operational performance of the CN 0° forward quasi-monoenergetic neutron capability in the 0.7--4 MeV range and identify the steps required toward routine calibrated operation.
title Development and validation of a forward 0.7--4 MeV quasi-monoenergetic neutron capability at the CN Van de Graaff of LNL
topic Instrumentation and Detectors
url https://arxiv.org/abs/2605.12005