Voxel-aware oxygen kinetics resolves radiation-induced DNA damage retention across LET-oxygen conditions

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Bolo, Renato III Fernan, Bagunu, Ramon Jose C.
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866916012480266240
author Bolo, Renato III Fernan
Bagunu, Ramon Jose C.
author_facet Bolo, Renato III Fernan
Bagunu, Ramon Jose C.
contents Objective. Hypoxic tumor subvolumes resist radiation through elevated oxygen enhancement ratios (OER), yet no computational OER model is simultaneously particle-specific, mechanistically grounded, and fast enough for voxel-scale treatment planning. We present the VOxel-Aware Oxygen Model (VOxA) to address all three requirements. Approach. An Oxygen Model (OM) encodes particle-specific LET-OER dependence through dual sigmoidal transitions constrained to increase monotonically with atomic number Z, combined with Michaelis-Menten oxygen kinetics. A Voxel-Aware (VA) extension resolves per-DSB local energy heterogeneity via a calibrated particle-specific sensitivity parameter. Calibrated on 233 OER observations from 29 sources across 10 particle types (LET = 0.2-654 keV/um); DSB coordinates from TOPAS-nBio simulations. Main results. The OM achieves $R^2 = 0.719$ and MAE = 0.300 retention OER units; theoretical OER maximum 3.32 (2.4% from measurement), bootstrap median 3.37 [3.18, 4.09]. The composite $K_{\rm fix} + K_{\rm repair} = 2.82$ mmHg is tightly constrained despite high collinearity (r = 0.935). On the Furusawa heavy-ion subset, VOxA achieves 28.4% lower survival OER MAE than the clinical standard (63.1% on helium, 24.0% on carbon) and reproduces He < C < Ne Z-ordering that universal models cannot capture. The VA extension passes 18 tests confirming sample-size-invariant within-nucleus coefficient of variation of the per-DSB retention probability. VOxA evaluates in under $10^{-3}$ ms per voxel, more than $10^6$ times faster than Monte Carlo chemistry. Significance. VOxA is the first particle-specific OER model to reproduce Z-ordering analytically at clinical planning speed, validated on the largest OER calibration dataset for this model class. Committed-break coordinates at whole-nuclear scale provide the input for inter-break topological analysis and hypoxic LET painting.
format Preprint
id arxiv_https___arxiv_org_abs_2605_12558
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Voxel-aware oxygen kinetics resolves radiation-induced DNA damage retention across LET-oxygen conditions
Bolo, Renato III Fernan
Bagunu, Ramon Jose C.
Medical Physics
Objective. Hypoxic tumor subvolumes resist radiation through elevated oxygen enhancement ratios (OER), yet no computational OER model is simultaneously particle-specific, mechanistically grounded, and fast enough for voxel-scale treatment planning. We present the VOxel-Aware Oxygen Model (VOxA) to address all three requirements. Approach. An Oxygen Model (OM) encodes particle-specific LET-OER dependence through dual sigmoidal transitions constrained to increase monotonically with atomic number Z, combined with Michaelis-Menten oxygen kinetics. A Voxel-Aware (VA) extension resolves per-DSB local energy heterogeneity via a calibrated particle-specific sensitivity parameter. Calibrated on 233 OER observations from 29 sources across 10 particle types (LET = 0.2-654 keV/um); DSB coordinates from TOPAS-nBio simulations. Main results. The OM achieves $R^2 = 0.719$ and MAE = 0.300 retention OER units; theoretical OER maximum 3.32 (2.4% from measurement), bootstrap median 3.37 [3.18, 4.09]. The composite $K_{\rm fix} + K_{\rm repair} = 2.82$ mmHg is tightly constrained despite high collinearity (r = 0.935). On the Furusawa heavy-ion subset, VOxA achieves 28.4% lower survival OER MAE than the clinical standard (63.1% on helium, 24.0% on carbon) and reproduces He < C < Ne Z-ordering that universal models cannot capture. The VA extension passes 18 tests confirming sample-size-invariant within-nucleus coefficient of variation of the per-DSB retention probability. VOxA evaluates in under $10^{-3}$ ms per voxel, more than $10^6$ times faster than Monte Carlo chemistry. Significance. VOxA is the first particle-specific OER model to reproduce Z-ordering analytically at clinical planning speed, validated on the largest OER calibration dataset for this model class. Committed-break coordinates at whole-nuclear scale provide the input for inter-break topological analysis and hypoxic LET painting.
title Voxel-aware oxygen kinetics resolves radiation-induced DNA damage retention across LET-oxygen conditions
topic Medical Physics
url https://arxiv.org/abs/2605.12558