DSTAN-Med: Dual-Channel Spatiotemporal Attention with Physiological Plausibility Filtering for False Data Injection Attack Detection in IoT-Based Medical Devices

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Hasan, Md Mehedi, Islam, Rafiqul, Hossain, Md Zakir
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866911683813834752
author Hasan, Md Mehedi
Islam, Rafiqul
Hossain, Md Zakir
author_facet Hasan, Md Mehedi
Islam, Rafiqul
Hossain, Md Zakir
contents False data injection (FDI) attacks on Internet of Medical Things (IoMT) sensor streams falsify vital signs in transit, threatening patient safety and defeating clinical monitoring systems that lack cyber-physical anomaly detection capability. Existing deep learning detectors conflate inter-sensor spatial correlations with temporal dependencies in a shared latent space, preventing disentanglement of the distinct spatial and temporal signatures that FDI attacks imprint simultaneously; no current method exploits domain knowledge to constrain outputs against physiologically impossible attack patterns. We propose DSTAN-Med, a supervised framework comprising a Dual-channel Attention Mechanism (DAM) that routes multivariate sensor windows through independent sensor-wise (SWA) and time-wise (TWA) self-attention pathways operating on orthogonal tensor axes, a residual 1D-CNN block for local temporal feature extraction, and a zero-parameter Physiological Plausibility Filter (PPF) that suppresses attack signatures violating domain-knowledge bounds. Evaluated across three IoMT sensor datasets - PhysioNet/CinC 2012 (ICU vital signs), MIMIC-III Waveform (continuous ICU waveforms), and WESAD (wearable biosensor signals) - DSTAN-Med achieves mean sensitivity gains of 7.4-8.3 percentage points over the strongest Transformer baseline (TranAD), with improvements significant at p < 0.01 (McNemar's test, Holm-Bonferroni correction). The PPF contributes independent precision gains of 3.1-4.2 percentage points at negligible sensitivity cost across all three corpora. Ablation studies confirm that each component is individually necessary; removal of residual connections alone reduces sensitivity by 14.0 percentage points. The source code is publicly available at https://github.com/mehedi93hasan/DSTAN-MED.
format Preprint
id arxiv_https___arxiv_org_abs_2605_14165
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle DSTAN-Med: Dual-Channel Spatiotemporal Attention with Physiological Plausibility Filtering for False Data Injection Attack Detection in IoT-Based Medical Devices
Hasan, Md Mehedi
Islam, Rafiqul
Hossain, Md Zakir
Cryptography and Security
False data injection (FDI) attacks on Internet of Medical Things (IoMT) sensor streams falsify vital signs in transit, threatening patient safety and defeating clinical monitoring systems that lack cyber-physical anomaly detection capability. Existing deep learning detectors conflate inter-sensor spatial correlations with temporal dependencies in a shared latent space, preventing disentanglement of the distinct spatial and temporal signatures that FDI attacks imprint simultaneously; no current method exploits domain knowledge to constrain outputs against physiologically impossible attack patterns. We propose DSTAN-Med, a supervised framework comprising a Dual-channel Attention Mechanism (DAM) that routes multivariate sensor windows through independent sensor-wise (SWA) and time-wise (TWA) self-attention pathways operating on orthogonal tensor axes, a residual 1D-CNN block for local temporal feature extraction, and a zero-parameter Physiological Plausibility Filter (PPF) that suppresses attack signatures violating domain-knowledge bounds. Evaluated across three IoMT sensor datasets - PhysioNet/CinC 2012 (ICU vital signs), MIMIC-III Waveform (continuous ICU waveforms), and WESAD (wearable biosensor signals) - DSTAN-Med achieves mean sensitivity gains of 7.4-8.3 percentage points over the strongest Transformer baseline (TranAD), with improvements significant at p < 0.01 (McNemar's test, Holm-Bonferroni correction). The PPF contributes independent precision gains of 3.1-4.2 percentage points at negligible sensitivity cost across all three corpora. Ablation studies confirm that each component is individually necessary; removal of residual connections alone reduces sensitivity by 14.0 percentage points. The source code is publicly available at https://github.com/mehedi93hasan/DSTAN-MED.
title DSTAN-Med: Dual-Channel Spatiotemporal Attention with Physiological Plausibility Filtering for False Data Injection Attack Detection in IoT-Based Medical Devices
topic Cryptography and Security
url https://arxiv.org/abs/2605.14165