RDDM: A Residual-Driven Drifting Model for High-Fidelity Low-Dose CT Denoising
Fuente:
arXiv
Gespeichert in:
| Hauptverfasser: | , , |
|---|---|
| Format: | Preprint |
| Veröffentlicht: |
2026
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1866914574724235264 |
|---|---|
| author | Wang, Jianxu Lyu, Qing Wang, Ge |
| author_facet | Wang, Jianxu Lyu, Qing Wang, Ge |
| contents | Low-dose CT (LDCT) denoising remains an important yet challenging problem in medical imaging. Although recent learning-based methods have shown promising performance, those optimized using classical pixel-level objectives often produce over-smoothed reconstructions. Existing mainstream generative models, such as diffusion models, have improved fidelity at the cost of expensive multi-step iterative inference, which limits their practicality for real-time use. To address this gap, we propose a Residual-Driven Drifting Model (RDDM) for effective, efficient, and high-fidelity LDCT denoising. Inspired by the recently proposed Drifting Models, RDDM incorporates the multi-step distribution evolution into the training dynamics through a residual drifting field, thereby enabling one-step denoising. Specifically, the residual drifting field is formed by an attractive force induced by the residuals between LDCT and normal-dose CT (NDCT) and a repulsive force induced by the generated residuals. In addition, by adjusting the parameter settings and incorporating pixel-level supervision, we develop three RDDM variants, covering application needs from detail preservation to stronger noise suppression. Extensive experiments demonstrate that RDDM achieves state-of-the-art denoising performance among supervised baselines. In particular, RDDM-Fine produces reconstructions that are highly consistent with NDCT, achieving superior PSNR and SSIM together with the best FID of 5.87 while preserving realistic anatomical textures. Moreover, RDDM enables on-the-fly inference, requiring only about 15 ms to denoise a single 512 x 512 LDCT slice. These results establish RDDM as a promising solution for high-fidelity and real-time LDCT denoising in clinical applications. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2605_17188 |
| institution | arXiv |
| publishDate | 2026 |
| record_format | arxiv |
| spellingShingle | RDDM: A Residual-Driven Drifting Model for High-Fidelity Low-Dose CT Denoising Wang, Jianxu Lyu, Qing Wang, Ge Image and Video Processing Low-dose CT (LDCT) denoising remains an important yet challenging problem in medical imaging. Although recent learning-based methods have shown promising performance, those optimized using classical pixel-level objectives often produce over-smoothed reconstructions. Existing mainstream generative models, such as diffusion models, have improved fidelity at the cost of expensive multi-step iterative inference, which limits their practicality for real-time use. To address this gap, we propose a Residual-Driven Drifting Model (RDDM) for effective, efficient, and high-fidelity LDCT denoising. Inspired by the recently proposed Drifting Models, RDDM incorporates the multi-step distribution evolution into the training dynamics through a residual drifting field, thereby enabling one-step denoising. Specifically, the residual drifting field is formed by an attractive force induced by the residuals between LDCT and normal-dose CT (NDCT) and a repulsive force induced by the generated residuals. In addition, by adjusting the parameter settings and incorporating pixel-level supervision, we develop three RDDM variants, covering application needs from detail preservation to stronger noise suppression. Extensive experiments demonstrate that RDDM achieves state-of-the-art denoising performance among supervised baselines. In particular, RDDM-Fine produces reconstructions that are highly consistent with NDCT, achieving superior PSNR and SSIM together with the best FID of 5.87 while preserving realistic anatomical textures. Moreover, RDDM enables on-the-fly inference, requiring only about 15 ms to denoise a single 512 x 512 LDCT slice. These results establish RDDM as a promising solution for high-fidelity and real-time LDCT denoising in clinical applications. |
| title | RDDM: A Residual-Driven Drifting Model for High-Fidelity Low-Dose CT Denoising |
| topic | Image and Video Processing |
| url | https://arxiv.org/abs/2605.17188 |