Environmental Stabilization of Perfect-Crystal Neutron Interferometry Using a Large Vacuum Chamber with Cryogenic Sample Access

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Valdillez, Robert, Cory, David G., Haun, Robert W., Heacock, Benjamin, Heikes, Colin, Hoogerheide, Shannon F., Huber, Michael G., Mineeva, Taisiya, Paster, Jeremy, Sarenac, Dusan, Pushin, Dmitry A., Young, Albert R.
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914579056951296
author Valdillez, Robert
Cory, David G.
Haun, Robert W.
Heacock, Benjamin
Heikes, Colin
Hoogerheide, Shannon F.
Huber, Michael G.
Mineeva, Taisiya
Paster, Jeremy
Sarenac, Dusan
Pushin, Dmitry A.
Young, Albert R.
author_facet Valdillez, Robert
Cory, David G.
Haun, Robert W.
Heacock, Benjamin
Heikes, Colin
Hoogerheide, Shannon F.
Huber, Michael G.
Mineeva, Taisiya
Paster, Jeremy
Sarenac, Dusan
Pushin, Dmitry A.
Young, Albert R.
contents Perfect-crystal neutron interferometry has been a useful tool in measuring nuclear-interactions, probing fundamental physics, and exploring quantum phenomenon. Historically, neutron interferometry experiments have been carried out at room temperature and standard atmospheric pressure. However, neutron interferometry is sensitive to changes in the local environment, especially thermal gradients across the crystal, resulting in phase drifts and systematic uncertainty. A need for measurements performed in different sample environments compound these issues. Fortunately, the use of a vacuum chamber has been shown to be an effective method of environmental isolation for perfect-crystal neutron interferometers. A large volume, highly versatile vacuum chamber has been installed at the Neutron Interferometry and Optics Facility at the NIST Center for Neutron Research to isolate interferometry from local temperature and pressure deviations as well as allowing for the introduction of cryogenically cooled samples. The prospect of incorporating a cryostat within a neutron interferometer opens up new areas of investigation, such as superconductivity. In addition to describing the vacuum chamber, we report on the first measurement of a cryogenic-cooled sample by a neutron interferometer. For this demonstration contrast was measured with a Ni60Cu40 sample between 4 K to 300 K.
format Preprint
id arxiv_https___arxiv_org_abs_2605_18874
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Environmental Stabilization of Perfect-Crystal Neutron Interferometry Using a Large Vacuum Chamber with Cryogenic Sample Access
Valdillez, Robert
Cory, David G.
Haun, Robert W.
Heacock, Benjamin
Heikes, Colin
Hoogerheide, Shannon F.
Huber, Michael G.
Mineeva, Taisiya
Paster, Jeremy
Sarenac, Dusan
Pushin, Dmitry A.
Young, Albert R.
Instrumentation and Detectors
Nuclear Experiment
Perfect-crystal neutron interferometry has been a useful tool in measuring nuclear-interactions, probing fundamental physics, and exploring quantum phenomenon. Historically, neutron interferometry experiments have been carried out at room temperature and standard atmospheric pressure. However, neutron interferometry is sensitive to changes in the local environment, especially thermal gradients across the crystal, resulting in phase drifts and systematic uncertainty. A need for measurements performed in different sample environments compound these issues. Fortunately, the use of a vacuum chamber has been shown to be an effective method of environmental isolation for perfect-crystal neutron interferometers. A large volume, highly versatile vacuum chamber has been installed at the Neutron Interferometry and Optics Facility at the NIST Center for Neutron Research to isolate interferometry from local temperature and pressure deviations as well as allowing for the introduction of cryogenically cooled samples. The prospect of incorporating a cryostat within a neutron interferometer opens up new areas of investigation, such as superconductivity. In addition to describing the vacuum chamber, we report on the first measurement of a cryogenic-cooled sample by a neutron interferometer. For this demonstration contrast was measured with a Ni60Cu40 sample between 4 K to 300 K.
title Environmental Stabilization of Perfect-Crystal Neutron Interferometry Using a Large Vacuum Chamber with Cryogenic Sample Access
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2605.18874