Procurement and Purification of Liquid Argon for the LEGEND-200 Experiment

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Harańczyk, Malgorzata, Krause, Patrick, Mróz, Tomasz, Papp, Laszlo, Pelczar, Krzysztof, Schönert, Stefan, Schwarz, Mario, Vogl, Christoph, Zuzel, Grzegorz, Balata, Marco, Burlac, Nina
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866913147254734848
author Harańczyk, Malgorzata
Krause, Patrick
Mróz, Tomasz
Papp, Laszlo
Pelczar, Krzysztof
Schönert, Stefan
Schwarz, Mario
Vogl, Christoph
Zuzel, Grzegorz
Balata, Marco
Burlac, Nina
author_facet Harańczyk, Malgorzata
Krause, Patrick
Mróz, Tomasz
Papp, Laszlo
Pelczar, Krzysztof
Schönert, Stefan
Schwarz, Mario
Vogl, Christoph
Zuzel, Grzegorz
Balata, Marco
Burlac, Nina
contents LEGEND-200 requires high-purity liquid argon for effective background discrimination. In this paper, we present the design, construction, and performance of a dedicated liquid argon purification system, along with the procurement and purification of liquid argon for filling the LEGEND-200 cryostat to its total capacity of 91 t. The purifier is based on copper catalyst and molecular sieve to remove oxygen and water. Starting with liquid argon of 5.5 quality, featuring an effective scintillation light triplet lifetime $τ_t$ of about 0.9 $μ$s, we achieved a final purity corresponding to $τ_t$ = 1.3 $μ$s. After complete filling of the LEGEND-200 cryostat, the measured effective triplet lifetime was 1.16 $μ$s. The notable reduction is caused by a residual nitrogen impurity introduced by an accidentally spoiled liquid argon delivery. An excessive nitrogen influx was prevented by the LEGEND Liquid Argon Monitoring Apparatus (LLAMA), which served as one of the three independent purity monitors during the filling campaign.
format Preprint
id arxiv_https___arxiv_org_abs_2605_20507
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Procurement and Purification of Liquid Argon for the LEGEND-200 Experiment
Harańczyk, Malgorzata
Krause, Patrick
Mróz, Tomasz
Papp, Laszlo
Pelczar, Krzysztof
Schönert, Stefan
Schwarz, Mario
Vogl, Christoph
Zuzel, Grzegorz
Balata, Marco
Burlac, Nina
Instrumentation and Detectors
LEGEND-200 requires high-purity liquid argon for effective background discrimination. In this paper, we present the design, construction, and performance of a dedicated liquid argon purification system, along with the procurement and purification of liquid argon for filling the LEGEND-200 cryostat to its total capacity of 91 t. The purifier is based on copper catalyst and molecular sieve to remove oxygen and water. Starting with liquid argon of 5.5 quality, featuring an effective scintillation light triplet lifetime $τ_t$ of about 0.9 $μ$s, we achieved a final purity corresponding to $τ_t$ = 1.3 $μ$s. After complete filling of the LEGEND-200 cryostat, the measured effective triplet lifetime was 1.16 $μ$s. The notable reduction is caused by a residual nitrogen impurity introduced by an accidentally spoiled liquid argon delivery. An excessive nitrogen influx was prevented by the LEGEND Liquid Argon Monitoring Apparatus (LLAMA), which served as one of the three independent purity monitors during the filling campaign.
title Procurement and Purification of Liquid Argon for the LEGEND-200 Experiment
topic Instrumentation and Detectors
url https://arxiv.org/abs/2605.20507