SDFStent: Real-time interactive virtual stenting via SDF deformation fields

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Li, Bohan J., Dorn, Nicholas C., Lasso, Andras, Jolley, Matthew A., Feinstein, Jeffrey A., James, Doug L., Marsden, Alison L.
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866917519084748800
author Li, Bohan J.
Dorn, Nicholas C.
Lasso, Andras
Jolley, Matthew A.
Feinstein, Jeffrey A.
James, Doug L.
Marsden, Alison L.
author_facet Li, Bohan J.
Dorn, Nicholas C.
Lasso, Andras
Jolley, Matthew A.
Feinstein, Jeffrey A.
James, Doug L.
Marsden, Alison L.
contents Stenting is among the most common transcatheter interventions for congenital heart disease (CHD). Patient-specific computational fluid dynamics (CFD) simulations can predict hemodynamic outcomes of intervention scenarios but require post-operative vascular geometries that reflect stent-induced shape changes, which existing tools either model inadequately or require extensive time or manual effort to generate. We present SDFStent, a signed distance function (SDF) based mesh deformation method for virtual stenting that operates in real time, maintains mesh integrity, and preserves junction geometry. The stent is modeled as a pipe surface composed of piecewise-capsule SDFs joined by a smooth-minimum operator. Mesh vertices near the expanding SDF surface are displaced along the SDF gradient with a compactly supported fall-off function and an alpha blending mask. SDFStent was benchmarked against three existing approaches and validated on three tetralogy of Fallot (ToF) patients and three coarctation of the aorta (CoA) patients using rigid-wall steady-state CFD simulations against clinical catheterization measurements. Against a prescribed diameter of 6.0 mm, the method produced a mean stented diameter of 5.92 $\pm$ 0.08 mm in 1.5 s, over 100$\times$ faster than the best stenting-specific comparator. All output meshes were watertight and self-intersection-free. CFD-simulated post-operative pressure drops agreed with clinical measurements within 4 mmHg (mean error 2 mmHg). SDFStent produces simulation-ready post-stent models that match prescribed stent dimensions at interactive speeds, from pre-operative anatomy and catheterization data alone. The implementation is open-source and available in 3D Slicer. Its scriptable architecture enables automated generation of large synthetic cohorts for data-driven surrogate modeling.
format Preprint
id arxiv_https___arxiv_org_abs_2605_22009
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle SDFStent: Real-time interactive virtual stenting via SDF deformation fields
Li, Bohan J.
Dorn, Nicholas C.
Lasso, Andras
Jolley, Matthew A.
Feinstein, Jeffrey A.
James, Doug L.
Marsden, Alison L.
Computational Engineering, Finance, and Science
Medical Physics
Quantitative Methods
Stenting is among the most common transcatheter interventions for congenital heart disease (CHD). Patient-specific computational fluid dynamics (CFD) simulations can predict hemodynamic outcomes of intervention scenarios but require post-operative vascular geometries that reflect stent-induced shape changes, which existing tools either model inadequately or require extensive time or manual effort to generate. We present SDFStent, a signed distance function (SDF) based mesh deformation method for virtual stenting that operates in real time, maintains mesh integrity, and preserves junction geometry. The stent is modeled as a pipe surface composed of piecewise-capsule SDFs joined by a smooth-minimum operator. Mesh vertices near the expanding SDF surface are displaced along the SDF gradient with a compactly supported fall-off function and an alpha blending mask. SDFStent was benchmarked against three existing approaches and validated on three tetralogy of Fallot (ToF) patients and three coarctation of the aorta (CoA) patients using rigid-wall steady-state CFD simulations against clinical catheterization measurements. Against a prescribed diameter of 6.0 mm, the method produced a mean stented diameter of 5.92 $\pm$ 0.08 mm in 1.5 s, over 100$\times$ faster than the best stenting-specific comparator. All output meshes were watertight and self-intersection-free. CFD-simulated post-operative pressure drops agreed with clinical measurements within 4 mmHg (mean error 2 mmHg). SDFStent produces simulation-ready post-stent models that match prescribed stent dimensions at interactive speeds, from pre-operative anatomy and catheterization data alone. The implementation is open-source and available in 3D Slicer. Its scriptable architecture enables automated generation of large synthetic cohorts for data-driven surrogate modeling.
title SDFStent: Real-time interactive virtual stenting via SDF deformation fields
topic Computational Engineering, Finance, and Science
Medical Physics
Quantitative Methods
url https://arxiv.org/abs/2605.22009