Comparing telluric removal methods in their capability to recover injected exoplanet atmosphere signals with high resolution emission spectroscopy

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Keniger, Marcelo Aron Fetzner, Brogi, Matteo, Armstrong, David, Gandhi, Siddharth
Format: Preprint
Veröffentlicht: 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866914608638328832
author Keniger, Marcelo Aron Fetzner
Brogi, Matteo
Armstrong, David
Gandhi, Siddharth
author_facet Keniger, Marcelo Aron Fetzner
Brogi, Matteo
Armstrong, David
Gandhi, Siddharth
contents For ground-based high-resolution spectroscopic exoplanet atmosphere studies, removing the contamination from telluric and stellar lines is a crucial step in the analysis process. Despite that, there is no consensus in the literature on the most appropriate way to carry this out. Typically, tellurics are either directly modelled to a percent-level precision, or blindly detrended via Principal Component Analysis (PCA) algorithms, the latter particularly common at infrared wavelengths. Here, we compare three different detrending methods, PCA, Molecfit and our own fitting algorithm Astroclimes, measuring their performance in the context of removing telluric and stellar lines to detect exoplanetary atmospheric signals. We specifically look for H2O detections, which are particularly affected by residual, time-correlated variability of the telluric spectrum. We use near-infrared CARMENES observations of the day-side of $τ$ Bootis b to carry out injection and recovery tests. We find that while PCA can sometimes achieve higher SNR, it comes at the expense of stronger signal degradation. All methods struggle more for injected signals with lower orbital velocities, not just affecting the signal's magnitude but its location in velocity space as well. This behaviour is more prominent for PCA than for Astroclimes and Molecfit. These results highlight the importance of understanding the effects of different detrending methods on exoplanetary signals, which can lead to biases when characterising real detections. Finally, we report that our attempts to detect a previously claimed water signal from $τ$ Bootis b all resulted in non-detections.
format Preprint
id arxiv_https___arxiv_org_abs_2605_28635
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Comparing telluric removal methods in their capability to recover injected exoplanet atmosphere signals with high resolution emission spectroscopy
Keniger, Marcelo Aron Fetzner
Brogi, Matteo
Armstrong, David
Gandhi, Siddharth
Earth and Planetary Astrophysics
Instrumentation and Methods for Astrophysics
For ground-based high-resolution spectroscopic exoplanet atmosphere studies, removing the contamination from telluric and stellar lines is a crucial step in the analysis process. Despite that, there is no consensus in the literature on the most appropriate way to carry this out. Typically, tellurics are either directly modelled to a percent-level precision, or blindly detrended via Principal Component Analysis (PCA) algorithms, the latter particularly common at infrared wavelengths. Here, we compare three different detrending methods, PCA, Molecfit and our own fitting algorithm Astroclimes, measuring their performance in the context of removing telluric and stellar lines to detect exoplanetary atmospheric signals. We specifically look for H2O detections, which are particularly affected by residual, time-correlated variability of the telluric spectrum. We use near-infrared CARMENES observations of the day-side of $τ$ Bootis b to carry out injection and recovery tests. We find that while PCA can sometimes achieve higher SNR, it comes at the expense of stronger signal degradation. All methods struggle more for injected signals with lower orbital velocities, not just affecting the signal's magnitude but its location in velocity space as well. This behaviour is more prominent for PCA than for Astroclimes and Molecfit. These results highlight the importance of understanding the effects of different detrending methods on exoplanetary signals, which can lead to biases when characterising real detections. Finally, we report that our attempts to detect a previously claimed water signal from $τ$ Bootis b all resulted in non-detections.
title Comparing telluric removal methods in their capability to recover injected exoplanet atmosphere signals with high resolution emission spectroscopy
topic Earth and Planetary Astrophysics
Instrumentation and Methods for Astrophysics
url https://arxiv.org/abs/2605.28635