Closed-Form Pose Estimation of Endoluminal Medical Devices via Gradiometer-Based Electromagnetic Localization System

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Wu, Zhiwei, Luo, Jiahao, Pu, Yubo, Wei, Siyi, Chen, Yuankai, Zhang, Jinhui
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866913179016101888
author Wu, Zhiwei
Luo, Jiahao
Pu, Yubo
Wei, Siyi
Chen, Yuankai
Zhang, Jinhui
author_facet Wu, Zhiwei
Luo, Jiahao
Pu, Yubo
Wei, Siyi
Chen, Yuankai
Zhang, Jinhui
contents Embedded magnetic tracking holds highly attractive prospects for remote navigation of endoluminal medical devices. However, existing six-degree-of-freedom pose recovery approaches often require pre-calibrated workspace field maps or iterative nonlinear optimization. This letter presents a Gradiometer-Based Electromagnetic Localization System (GELS), a closed-form tracking framework that uses a compact magnetometer array as an embedded quasi-gradiometer to estimate local magnetic fields and gradient tensors. These quantities are mapped by the Euler homogeneous relation to displacements between source and array, from which multi-source Procrustes registration recovers the array orientation and position using at least three non-collinear sources. The algorithm requires known source positions and array geometry, but no pre-calibrated workspace field maps, initial pose guesses, or calibrated excitation-source moments. The recovered pose also enables a proof-of-concept sub-level dipole localization task by serving as a mobile magnetic reference frame. Benchtop experiments across sensor-array configurations and excitation modes demonstrate sequence-averaged position errors of \SI{10.80}{\milli\meter}--\SI{15.57}{\milli\meter}, a fastest update rate of \SI{14.49}{\hertz}, and a median solver runtime of \SI{172.00}{\micro\second}. A perturbation-based error propagation analysis further identifies inter-sensor inconsistency and dipole-model mismatch as the dominant accuracy limits, thereby informing future sensor array and magnetic source design for further reducing pose-estimation error.
format Preprint
id arxiv_https___arxiv_org_abs_2606_01946
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Closed-Form Pose Estimation of Endoluminal Medical Devices via Gradiometer-Based Electromagnetic Localization System
Wu, Zhiwei
Luo, Jiahao
Pu, Yubo
Wei, Siyi
Chen, Yuankai
Zhang, Jinhui
Robotics
Embedded magnetic tracking holds highly attractive prospects for remote navigation of endoluminal medical devices. However, existing six-degree-of-freedom pose recovery approaches often require pre-calibrated workspace field maps or iterative nonlinear optimization. This letter presents a Gradiometer-Based Electromagnetic Localization System (GELS), a closed-form tracking framework that uses a compact magnetometer array as an embedded quasi-gradiometer to estimate local magnetic fields and gradient tensors. These quantities are mapped by the Euler homogeneous relation to displacements between source and array, from which multi-source Procrustes registration recovers the array orientation and position using at least three non-collinear sources. The algorithm requires known source positions and array geometry, but no pre-calibrated workspace field maps, initial pose guesses, or calibrated excitation-source moments. The recovered pose also enables a proof-of-concept sub-level dipole localization task by serving as a mobile magnetic reference frame. Benchtop experiments across sensor-array configurations and excitation modes demonstrate sequence-averaged position errors of \SI{10.80}{\milli\meter}--\SI{15.57}{\milli\meter}, a fastest update rate of \SI{14.49}{\hertz}, and a median solver runtime of \SI{172.00}{\micro\second}. A perturbation-based error propagation analysis further identifies inter-sensor inconsistency and dipole-model mismatch as the dominant accuracy limits, thereby informing future sensor array and magnetic source design for further reducing pose-estimation error.
title Closed-Form Pose Estimation of Endoluminal Medical Devices via Gradiometer-Based Electromagnetic Localization System
topic Robotics
url https://arxiv.org/abs/2606.01946