Saved in:
Bibliographic Details
Main Author: Kähler, Paul
Format: Dataset Open Access
Language:en
Published: PANGAEA 2008
Subjects:
Online Access:https://doi.org/10.1594/PANGAEA.696268
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867171356670427136
author Kähler, Paul
author_facet Kähler, Paul
collection Datos científicos de ciencias marinas y ambientales
contents Not filtered water samples were taken in 10 ml ampoules (sealed immediately after being acidified with phosphoric acid to pH<2, sampling), or 40 ml screw-lid vials, and measured onboard at sampling or next days, or frozen (-20°C) until being acidified and measured in home labs. Carbon measurement was by high-temperature catalytic oxydation in a 10 cm column packed with 5% Pt on aluminum oxide beads at 900°C in a stream of oxygen, and CO2 detection by infrared extinction after the removal of moisture and SO2 by appropriate traps (cold trap, Mg-percarbonate, Na-pyrophosphate, tin, bronze or Sulfix). The apparatus was the dual channel Dimatek 2000 equipped with a Binos 200 detector.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_696268
institution PANGAEA
language en
publishDate 2008
publisher PANGAEA
record_format pangaea
spellingShingle Concentrations of total organic carbon on vertical profiles in waters of the North Atlantic in January 1994
Kähler, Paul
CTD/Rosette; CTD-RO; M27/2; M27/2-CTD-026_022; M27/2-CTD-027_023; M27/2-CTD-028_024; M27/2-CTD-029_025; M27/2-CTD-030_026; M27/2-CTD-031_027; M27/2-CTD-032_028; M27/2-CTD-033_029; M27/2-CTD-034_030; M27/2-CTD-035_031; Meteor (1986)
Not filtered water samples were taken in 10 ml ampoules (sealed immediately after being acidified with phosphoric acid to pH<2, sampling), or 40 ml screw-lid vials, and measured onboard at sampling or next days, or frozen (-20°C) until being acidified and measured in home labs. Carbon measurement was by high-temperature catalytic oxydation in a 10 cm column packed with 5% Pt on aluminum oxide beads at 900°C in a stream of oxygen, and CO2 detection by infrared extinction after the removal of moisture and SO2 by appropriate traps (cold trap, Mg-percarbonate, Na-pyrophosphate, tin, bronze or Sulfix). The apparatus was the dual channel Dimatek 2000 equipped with a Binos 200 detector.
title Concentrations of total organic carbon on vertical profiles in waters of the North Atlantic in January 1994
topic CTD/Rosette; CTD-RO; M27/2; M27/2-CTD-026_022; M27/2-CTD-027_023; M27/2-CTD-028_024; M27/2-CTD-029_025; M27/2-CTD-030_026; M27/2-CTD-031_027; M27/2-CTD-032_028; M27/2-CTD-033_029; M27/2-CTD-034_030; M27/2-CTD-035_031; Meteor (1986)
url https://doi.org/10.1594/PANGAEA.696268