(Table 1) Heat flow measurements in the Gulf of Aden
Fuente:
PANGAEA
Guardado en:
| Autor principal: | |
|---|---|
| Formato: | Dataset Open Access |
| Lenguaje: | en |
| Publicado: |
PANGAEA
1986
|
| Materias: | |
| Acceso en línea: | |
| Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
| _version_ | 1867170911768018944 |
|---|---|
| author | Zolotarev, Vladimir G |
| author_facet | Zolotarev, Vladimir G |
| collection | Datos científicos de ciencias marinas y ambientales |
| contents | Heat fllow in the Tadjoura rift ranges from 158 to 348 mW/m**2. Under these conditions convection rate with intrinsic liquid temperature of 60°C is 2.5 m/yr. A body producing heat flow anomaly is a plate inclined toward the Arabian plate at an angle of 10° to vertical. The upper edge of the plate locates at depth of 6 km and its base locates at 45 km. 1300°C isotherm locates at depth of 30 km at distance of 160 km from the constructive boundary. |
| format | Dataset Open Access |
| id | pangaea_https___doi_org_10_1594_PANGAEA_756477 |
| institution | PANGAEA |
| language | en |
| publishDate | 1986 |
| publisher | PANGAEA |
| record_format | pangaea |
| spellingShingle | (Table 1) Heat flow measurements in the Gulf of Aden Zolotarev, Vladimir G Akademik Mstislav Keldysh; AMK7; AMK7-724; AMK7-733; AMK7-778; AMK7-785; AMK7-794; AMK7-823; Archive of Ocean Data; ARCOD; Calculated; Conductivity, thermal; Event label; Gulf of Aden; Heat flow; Heat flow, standard deviation; Latitude of event; Longitude of event; MULT; Multiple investigations; Temperature (thermal) gradient; Thermal conductive detector (TCD); Thermogradient meter Heat fllow in the Tadjoura rift ranges from 158 to 348 mW/m**2. Under these conditions convection rate with intrinsic liquid temperature of 60°C is 2.5 m/yr. A body producing heat flow anomaly is a plate inclined toward the Arabian plate at an angle of 10° to vertical. The upper edge of the plate locates at depth of 6 km and its base locates at 45 km. 1300°C isotherm locates at depth of 30 km at distance of 160 km from the constructive boundary. |
| title | (Table 1) Heat flow measurements in the Gulf of Aden |
| topic | Akademik Mstislav Keldysh; AMK7; AMK7-724; AMK7-733; AMK7-778; AMK7-785; AMK7-794; AMK7-823; Archive of Ocean Data; ARCOD; Calculated; Conductivity, thermal; Event label; Gulf of Aden; Heat flow; Heat flow, standard deviation; Latitude of event; Longitude of event; MULT; Multiple investigations; Temperature (thermal) gradient; Thermal conductive detector (TCD); Thermogradient meter |
| url | https://doi.org/10.1594/PANGAEA.756477 |