Enregistré dans:
Détails bibliographiques
Auteur principal: Lindemann, Christian
Format: Dataset Open Access
Langue:en
Publié: PANGAEA 2014
Sujets:
Accès en ligne:https://doi.org/10.1594/PANGAEA.838058
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1867170050310406144
author Lindemann, Christian
author_facet Lindemann, Christian
collection Datos científicos de ciencias marinas y ambientales
contents Oxygen concentration and rate of change of oxygen were measured using the Unisense Oxygen Microsensor System. Water from different depth was taken from CTD attached niskin bottle. Measurements were conducted in 2 ml vials provided by Unisense and lasted for a minimum of two minutes after a stable rate was achieved. The sampling interval was 6 seconds. Transport containers, tubes and vials for measurements were covered with light proof black foil for dark-measurements. Measurements labeled "unfiltered" were passed through a 200 µm sieve in order to remove potential biases stemming from individual meso-zooplankton. Measurements labeled "filtered" were passed through a 0.8 µm polycarbonate filter placed on top of a wetted GF/F filter.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_838058
institution PANGAEA
language en
publishDate 2014
publisher PANGAEA
record_format pangaea
spellingShingle Ex situ respiration rates measured in water column samples during the METEOR cruise M87/1 in April 2012
Lindemann, Christian
Basin Scale Analysis, Synthesis and Integration; Chlorophyll total; Coefficient of determination; CTD/Rosette; CTD-RO; Date/Time of event; Deep Convection Cruise; DEPTH, water; EURO-BASIN; Event label; Latitude of event; Longitude of event; M87/1_578-1; M87/1_624-1; M87/1_659-1; M87/1_679-1; M87/1b; Meteor (1986); Oxygen; Oxygen microelectrode, ex-situ; Respiration rate, oxygen; Station 1; Station 2; Treatment
Oxygen concentration and rate of change of oxygen were measured using the Unisense Oxygen Microsensor System. Water from different depth was taken from CTD attached niskin bottle. Measurements were conducted in 2 ml vials provided by Unisense and lasted for a minimum of two minutes after a stable rate was achieved. The sampling interval was 6 seconds. Transport containers, tubes and vials for measurements were covered with light proof black foil for dark-measurements. Measurements labeled "unfiltered" were passed through a 200 µm sieve in order to remove potential biases stemming from individual meso-zooplankton. Measurements labeled "filtered" were passed through a 0.8 µm polycarbonate filter placed on top of a wetted GF/F filter.
title Ex situ respiration rates measured in water column samples during the METEOR cruise M87/1 in April 2012
topic Basin Scale Analysis, Synthesis and Integration; Chlorophyll total; Coefficient of determination; CTD/Rosette; CTD-RO; Date/Time of event; Deep Convection Cruise; DEPTH, water; EURO-BASIN; Event label; Latitude of event; Longitude of event; M87/1_578-1; M87/1_624-1; M87/1_659-1; M87/1_679-1; M87/1b; Meteor (1986); Oxygen; Oxygen microelectrode, ex-situ; Respiration rate, oxygen; Station 1; Station 2; Treatment
url https://doi.org/10.1594/PANGAEA.838058