XCO2 and XCH4 total column measurement during POLARSTERN cruise PS83 (ANT-XXIX/10), north-south gradient

Fuente: PANGAEA
Saved in:
Bibliographic Details
Main Authors: Klappenbach, Friedrich, Bertleff, Marco, Kostinek, Julian, Hase, Frank, Blumenstock, Thomas, Agusti-Panareda, Anna, Razinger, Miha, Butz, André
Format: Dataset Open Access
Language:en
Published: PANGAEA 2015
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867171367951007744
author Klappenbach, Friedrich
Bertleff, Marco
Kostinek, Julian
Hase, Frank
Blumenstock, Thomas
Agusti-Panareda, Anna
Razinger, Miha
Butz, André
author_facet Klappenbach, Friedrich
Bertleff, Marco
Kostinek, Julian
Hase, Frank
Blumenstock, Thomas
Agusti-Panareda, Anna
Razinger, Miha
Butz, André
collection Datos científicos de ciencias marinas y ambientales
contents A portable Fourier transform spectrometer (FTS), model EM27/SUN, was deployed onboard the research vessel Polarstern to measure the column-average dry air mole fractions of carbon dioxide (XCO2) and methane (XCH4) by means of direct sunlight absorption spectrometry. We report on technical developments as well as data calibration and reduction measures required to achieve the targeted accuracy of fractions of a percent in retrieved XCO2 and XCH4 while operating the instrument under field conditions onboard the moving platform during a 6-week cruise on the Atlantic from Cape Town (South Africa, 34° S, 18° E; 5 March 2014) to Bremerhaven (Germany, 54° N, 19° E; 14 April 2014). We demonstrate that our solar tracker typically achieved a tracking precision of better than 0.05° toward the center of the sun throughout the ship cruise which facilitates accurate XCO2 and XCH4 retrievals even under harsh ambient wind conditions. We define several quality filters that screen spectra, e.g., when the field of view was partially obstructed by ship structures or when the lines-of-sight crossed the ship exhaust plume. The measurements in clean oceanic air, can be used to characterize a spurious air-mass dependency. After the campaign, deployment of the spectrometer alongside the TCCON (Total Carbon Column Observing Network) instrument at Karlsruhe, Germany, allowed for determining a calibration factor that makes the entire campaign record traceable to World Meteorological Organization (WMO) standards. Comparisons to observations of the GOSAT satellite and concentration fields modeled by the European Centre for Medium-Range Weather Forecasts (ECMWF) Copernicus Atmosphere Monitoring Service (CAMS) demonstrate that the observational setup is well suited to provide validation opportunities above the ocean and along interhemispheric transects.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_843880
institution PANGAEA
language en
publishDate 2015
publisher PANGAEA
record_format pangaea
spellingShingle XCO2 and XCH4 total column measurement during POLARSTERN cruise PS83 (ANT-XXIX/10), north-south gradient
Klappenbach, Friedrich
Bertleff, Marco
Kostinek, Julian
Hase, Frank
Blumenstock, Thomas
Agusti-Panareda, Anna
Razinger, Miha
Butz, André

A portable Fourier transform spectrometer (FTS), model EM27/SUN, was deployed onboard the research vessel Polarstern to measure the column-average dry air mole fractions of carbon dioxide (XCO2) and methane (XCH4) by means of direct sunlight absorption spectrometry. We report on technical developments as well as data calibration and reduction measures required to achieve the targeted accuracy of fractions of a percent in retrieved XCO2 and XCH4 while operating the instrument under field conditions onboard the moving platform during a 6-week cruise on the Atlantic from Cape Town (South Africa, 34° S, 18° E; 5 March 2014) to Bremerhaven (Germany, 54° N, 19° E; 14 April 2014). We demonstrate that our solar tracker typically achieved a tracking precision of better than 0.05° toward the center of the sun throughout the ship cruise which facilitates accurate XCO2 and XCH4 retrievals even under harsh ambient wind conditions. We define several quality filters that screen spectra, e.g., when the field of view was partially obstructed by ship structures or when the lines-of-sight crossed the ship exhaust plume. The measurements in clean oceanic air, can be used to characterize a spurious air-mass dependency. After the campaign, deployment of the spectrometer alongside the TCCON (Total Carbon Column Observing Network) instrument at Karlsruhe, Germany, allowed for determining a calibration factor that makes the entire campaign record traceable to World Meteorological Organization (WMO) standards. Comparisons to observations of the GOSAT satellite and concentration fields modeled by the European Centre for Medium-Range Weather Forecasts (ECMWF) Copernicus Atmosphere Monitoring Service (CAMS) demonstrate that the observational setup is well suited to provide validation opportunities above the ocean and along interhemispheric transects.