Data and codes used to reproduce the sample attenuation tomography at Mount St. Helens volcano

Fuente: PANGAEA
Guardado en:
Detalles Bibliográficos
Autores principales: De Siena, Luca, Thomas, Christine, Aster, Rick
Formato: Dataset Open Access
Lenguaje:en
Publicado: PANGAEA 2014
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1867171845464129536
author De Siena, Luca
Thomas, Christine
Aster, Rick
author_facet De Siena, Luca
Thomas, Christine
Aster, Rick
collection Datos científicos de ciencias marinas y ambientales
contents The attenuation of body-wave amplitudes with propagation distance can be used to provide detailed tomographic images of seismic interfaces, fluid reservoirs, and melt batches in the crust. The high sensitivity of body-wave energies to high-scattering structures becomes an obstacle when we try to apply attenuation tomography to small-scale volcanic media, where we must take into account the complexities induced by strong heterogeneous scattering, topography, and uncertain source modeling in the recorded wave-fields. The MuRAT code uses a source- and site-independent coda-normalization method to obtain frequency-dependent measurements of P-to-coda and S-to-coda energy ratios. The code inverts these data for both the geometrical spreading factor and the spatially-dependent quality factors (Q), providing additional attenuation information in the regions where velocity tomography is available. The high sensitivity of coda-waves to highly heterogeneous structures highlights zones of anomalous scattering, which may corrupt amplitude-dependent attenuation measurements, and where basal assumptions of linear optics may go unfulfilled. A multi-step tomographic inversion increases the stability of the results obtained in regions of high heterogeneity (e.g., the volcanic edifice) by the inclusion of data corresponding to either sources or stations located in regions of lower heterogeneity. On the other hand, a mere increase in the number of rays entirely contained in the heterogeneous structures affects both the stability and the effective resolution of the results. We apply the code to two small waveform datasets recorded at an active (Mount St. Helens) and at a quiescent (Mount Vesuvius) volcano. The results show that the seismicity located inside or under the volcanic edifice produces an increase of the low-frequency energy ratios with travel time in both areas. In our interpretation, the anomalous concentration of energy which affects any waveform recorded on the cone, produced inside the volcanic edifice or in the feeding system of the volcano is due to seismic source- or medium-dependent resonance. The results also provide spatial and frequency limits on the feasibility of attenuation tomography in these two regions with larger datasets.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_871091
institution PANGAEA
language en
publishDate 2014
publisher PANGAEA
record_format pangaea
spellingShingle Data and codes used to reproduce the sample attenuation tomography at Mount St. Helens volcano
De Siena, Luca
Thomas, Christine
Aster, Rick
Mount_St_Helens; Mount St. Helens, USA
The attenuation of body-wave amplitudes with propagation distance can be used to provide detailed tomographic images of seismic interfaces, fluid reservoirs, and melt batches in the crust. The high sensitivity of body-wave energies to high-scattering structures becomes an obstacle when we try to apply attenuation tomography to small-scale volcanic media, where we must take into account the complexities induced by strong heterogeneous scattering, topography, and uncertain source modeling in the recorded wave-fields. The MuRAT code uses a source- and site-independent coda-normalization method to obtain frequency-dependent measurements of P-to-coda and S-to-coda energy ratios. The code inverts these data for both the geometrical spreading factor and the spatially-dependent quality factors (Q), providing additional attenuation information in the regions where velocity tomography is available. The high sensitivity of coda-waves to highly heterogeneous structures highlights zones of anomalous scattering, which may corrupt amplitude-dependent attenuation measurements, and where basal assumptions of linear optics may go unfulfilled. A multi-step tomographic inversion increases the stability of the results obtained in regions of high heterogeneity (e.g., the volcanic edifice) by the inclusion of data corresponding to either sources or stations located in regions of lower heterogeneity. On the other hand, a mere increase in the number of rays entirely contained in the heterogeneous structures affects both the stability and the effective resolution of the results. We apply the code to two small waveform datasets recorded at an active (Mount St. Helens) and at a quiescent (Mount Vesuvius) volcano. The results show that the seismicity located inside or under the volcanic edifice produces an increase of the low-frequency energy ratios with travel time in both areas. In our interpretation, the anomalous concentration of energy which affects any waveform recorded on the cone, produced inside the volcanic edifice or in the feeding system of the volcano is due to seismic source- or medium-dependent resonance. The results also provide spatial and frequency limits on the feasibility of attenuation tomography in these two regions with larger datasets.
title Data and codes used to reproduce the sample attenuation tomography at Mount St. Helens volcano
topic Mount_St_Helens; Mount St. Helens, USA
url https://doi.org/10.1594/PANGAEA.871091