_version_ 1867172128326942720
author Naylor, Travis A
Phillips, Frances
author_facet Naylor, Travis A
Phillips, Frances
collection Datos científicos de ciencias marinas y ambientales
contents Date of Operation: 6-July 2017 to 14-September-2017 10:00 Location: Roof of 2 storey building at 2 Percy St, Auburn NSW 2144, Australia, -33.85472, 151.0373, 23.6 m above sea level, height mid-sonic above street level = 8.7 m, height mid-sonic above roof top=2.01 m Data collection rate: 10 Hz, average 5 min, timestamp end of collection period Bearing: 266 deg less 8 deg for offset Interruptions: logging program updated 14-July-2017 14:30 Issues: There was difficulty in determining the orientation of the 3D-sonic due to the surrounding infrastructure and nearby high tension electrical power lines. Final orientation was determined using GPS locations, and verified by comparison with wind direction data from the Australian Bureau of Meteorology (BoM), Sydney Olympic Park AWS site (station number 066212, -33.8338, 151.0718). The average difference in measured wind direction to Olympic Park AWS was +8 +/- 20 deg (+/-1s.d.,N=1037, Wind speed > 1m/s) and 8 degrees has been subtracted from the recorded wind directions.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_884311
institution PANGAEA
language en
publishDate 2017
publisher PANGAEA
record_format pangaea
spellingShingle 3D-Sonic Anemometer measurements of trace gases relevant to air quality in Western Sydney, Australia from 06 July 2017 to 14 September 2017
Naylor, Travis A
Phillips, Frances
3D Sonic CSAT3, Campbell Scientific Inc. with CR5000 logger; Air chemistry observatory; Auburn_PercySt; Australia; Covariance; DATE/TIME; Friction velocity; Heat, flux, sensible; HEIGHT above ground; ORDINAL NUMBER; Shear stress; Sonic temperature; SPUSO; Velocity relative to bottom X; Velocity relative to bottom Y; Velocity relative to bottom Z; Wind direction; Wind direction, standard deviation; Wind speed
Date of Operation: 6-July 2017 to 14-September-2017 10:00 Location: Roof of 2 storey building at 2 Percy St, Auburn NSW 2144, Australia, -33.85472, 151.0373, 23.6 m above sea level, height mid-sonic above street level = 8.7 m, height mid-sonic above roof top=2.01 m Data collection rate: 10 Hz, average 5 min, timestamp end of collection period Bearing: 266 deg less 8 deg for offset Interruptions: logging program updated 14-July-2017 14:30 Issues: There was difficulty in determining the orientation of the 3D-sonic due to the surrounding infrastructure and nearby high tension electrical power lines. Final orientation was determined using GPS locations, and verified by comparison with wind direction data from the Australian Bureau of Meteorology (BoM), Sydney Olympic Park AWS site (station number 066212, -33.8338, 151.0718). The average difference in measured wind direction to Olympic Park AWS was +8 +/- 20 deg (+/-1s.d.,N=1037, Wind speed > 1m/s) and 8 degrees has been subtracted from the recorded wind directions.
title 3D-Sonic Anemometer measurements of trace gases relevant to air quality in Western Sydney, Australia from 06 July 2017 to 14 September 2017
topic 3D Sonic CSAT3, Campbell Scientific Inc. with CR5000 logger; Air chemistry observatory; Auburn_PercySt; Australia; Covariance; DATE/TIME; Friction velocity; Heat, flux, sensible; HEIGHT above ground; ORDINAL NUMBER; Shear stress; Sonic temperature; SPUSO; Velocity relative to bottom X; Velocity relative to bottom Y; Velocity relative to bottom Z; Wind direction; Wind direction, standard deviation; Wind speed
url https://doi.org/10.1594/PANGAEA.884311