Saved in:
| Main Authors: | , |
|---|---|
| Format: | Dataset Open Access |
| Language: | en |
| Published: |
PANGAEA
2019
|
| Subjects: | |
| Online Access: | https://doi.org/10.1594/PANGAEA.908206 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1867171290314440704 |
|---|---|
| author | Cobb, Alexander R Harvey, Charles Franklin |
| author_facet | Cobb, Alexander R Harvey, Charles Franklin |
| collection | Datos científicos de ciencias marinas y ambientales |
| contents | Water level data were obtained from logging pressure transducers (Solinst Levelogger Edge 3001, Solinst Canada, Georgetown, Ontario, Canada) corrected for barometeric fluctuations using a barometer (Solinst Barologger Gold 3001). Each transducer was suspended on a steel cable inside a 2" PVC pipe 1.5 m in length installed to 1.4 m depth and screened at 1.3--1.45 m below the top of the piezometer casing. Piezometers were developed prior to measurement by repeatedly plunging and removing a solid rod into the piezometer tube. The details of how the surface datum was obtained are described in Cobb et al (2017, doi:10.1073/pnas.1701090114). |
| format | Dataset Open Access |
| id | pangaea_https___doi_org_10_1594_PANGAEA_908206 |
| institution | PANGAEA |
| language | en |
| publishDate | 2019 |
| publisher | PANGAEA |
| record_format | pangaea |
| spellingShingle | Water level data of mdm trail 7 from the Mendaram peat swamp in Brunei Darussalam Cobb, Alexander R Harvey, Charles Franklin Brunei_Darussalam_mdm_trail_7; DATE/TIME; hydraulic conductivity; Solinst Levelogger; specific yield; throughfall; tropical peat swamp; Water level; water table Water level data were obtained from logging pressure transducers (Solinst Levelogger Edge 3001, Solinst Canada, Georgetown, Ontario, Canada) corrected for barometeric fluctuations using a barometer (Solinst Barologger Gold 3001). Each transducer was suspended on a steel cable inside a 2" PVC pipe 1.5 m in length installed to 1.4 m depth and screened at 1.3--1.45 m below the top of the piezometer casing. Piezometers were developed prior to measurement by repeatedly plunging and removing a solid rod into the piezometer tube. The details of how the surface datum was obtained are described in Cobb et al (2017, doi:10.1073/pnas.1701090114). |
| title | Water level data of mdm trail 7 from the Mendaram peat swamp in Brunei Darussalam |
| topic | Brunei_Darussalam_mdm_trail_7; DATE/TIME; hydraulic conductivity; Solinst Levelogger; specific yield; throughfall; tropical peat swamp; Water level; water table |
| url | https://doi.org/10.1594/PANGAEA.908206 |