Saved in:
Bibliographic Details
Main Authors: Cobb, Alexander R, Harvey, Charles Franklin
Format: Dataset Open Access
Language:en
Published: PANGAEA 2019
Subjects:
Online Access:https://doi.org/10.1594/PANGAEA.908206
Tags: Add Tag
No Tags, Be the first to tag this record!
Table of Contents:
  • Water level data were obtained from logging pressure transducers (Solinst Levelogger Edge 3001, Solinst Canada, Georgetown, Ontario, Canada) corrected for barometeric fluctuations using a barometer (Solinst Barologger Gold 3001). Each transducer was suspended on a steel cable inside a 2" PVC pipe 1.5 m in length installed to 1.4 m depth and screened at 1.3--1.45 m below the top of the piezometer casing. Piezometers were developed prior to measurement by repeatedly plunging and removing a solid rod into the piezometer tube. The details of how the surface datum was obtained are described in Cobb et al (2017, doi:10.1073/pnas.1701090114).