Free Fall Cone Penetration Testing in Lake Zurich (Switzerland), 2015

Fuente: PANGAEA
Guardado en:
Detalles Bibliográficos
Autores principales: Strupler, Michael, Hilbe, Michael, Anselmetti, Flavio S, Kopf, Achim J, Fleischmann, Timo, Strasser, Michael
Formato: Dataset Open Access
Lenguaje:en
Publicado: PANGAEA 2020
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1867170100464844800
author Strupler, Michael
Hilbe, Michael
Anselmetti, Flavio S
Kopf, Achim J
Fleischmann, Timo
Strasser, Michael
author_facet Strupler, Michael
Hilbe, Michael
Anselmetti, Flavio S
Kopf, Achim J
Fleischmann, Timo
Strasser, Michael
collection Datos científicos de ciencias marinas y ambientales
contents In situ profiles were measured using a free-fall CPT probe from Marum, Bremen (Stegmann et al. 2006a, 2006b) deployed from the ARARAT platform. The apparatus derives undrained shear strength from the measured resistance of the cone and the sleeve of the probe (Stegmann et al. 2006b). Configuration of the CPT length was adapted to thicknesses of seismic stratigraphic units, and varied between 2 and 6 m. For a more detailed information on CPT testing and processing, refer to Steiner et al. (2012) and Steiner (2013).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_918182
institution PANGAEA
language en
publishDate 2020
publisher PANGAEA
record_format pangaea
spellingShingle Free Fall Cone Penetration Testing in Lake Zurich (Switzerland), 2015
Strupler, Michael
Hilbe, Michael
Anselmetti, Flavio S
Kopf, Achim J
Fleischmann, Timo
Strasser, Michael
File format; File name; File size; Free Fall CPU; Lake_Zurich; Lake Zurich; Slope stability; Switzerland; Uniform resource locator/link to file
In situ profiles were measured using a free-fall CPT probe from Marum, Bremen (Stegmann et al. 2006a, 2006b) deployed from the ARARAT platform. The apparatus derives undrained shear strength from the measured resistance of the cone and the sleeve of the probe (Stegmann et al. 2006b). Configuration of the CPT length was adapted to thicknesses of seismic stratigraphic units, and varied between 2 and 6 m. For a more detailed information on CPT testing and processing, refer to Steiner et al. (2012) and Steiner (2013).
title Free Fall Cone Penetration Testing in Lake Zurich (Switzerland), 2015
topic File format; File name; File size; Free Fall CPU; Lake_Zurich; Lake Zurich; Slope stability; Switzerland; Uniform resource locator/link to file
url https://doi.org/10.1594/PANGAEA.918182