Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Dataset Open Access |
| Language: | en |
| Published: |
PANGAEA
2020
|
| Subjects: | |
| Online Access: | https://doi.org/10.1594/PANGAEA.919103 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1867170101237645312 |
|---|---|
| author | Hillel, Noa Geyer, Stefan Licha, Tobias Khayat, Saed Laronne, Jonathan B Siebert, Christian |
| author_facet | Hillel, Noa Geyer, Stefan Licha, Tobias Khayat, Saed Laronne, Jonathan B Siebert, Christian |
| collection | Datos científicos de ciencias marinas y ambientales |
| contents | In February 2010, a hydrometric station was installed at the ''Qasser al-Yahud'' baptism site (740992E, 3525198N UTM Z36) in the Lower Jordan River, including an automatic water sampler (Andress and Hauser Liquiport 2000), and an independent EC-sensor (Condumax CLS12). In total, 428 water samples representing the time period 2010/03/26- 2012/07/09 were collected, filtered (0.22 µm PVDF) and analyzed for anions (Cl, Br, NO3, SO4) applying IC Dionex DX-320 and for cations (Na, K, Mg, Ca) applying IC Dionex DX-500, both with conductometric detection. |
| format | Dataset Open Access |
| id | pangaea_https___doi_org_10_1594_PANGAEA_919103 |
| institution | PANGAEA |
| language | en |
| publishDate | 2020 |
| publisher | PANGAEA |
| record_format | pangaea |
| spellingShingle | Water quality data of the Lower Jordan River 2010-2012 Hillel, Noa Geyer, Stefan Licha, Tobias Khayat, Saed Laronne, Jonathan B Siebert, Christian Automatic water sampler (Andress and Hauser Liquiport 2000); Bromide; Calcium; Chloride; Conductivity; CTD, Sea-Bird, SBE 911; DATE/TIME; Ion chromatograph, Dionex Corporation, DX-320; Ion chromatograph, Dionex Corporation, DX-500; Jordan, Israel, Asia; Jordan River; Magnesium; Nitrate; pollution; Potassium; Qasser_al-Yahud; Salinity; Sodium; Sulfate; water quality In February 2010, a hydrometric station was installed at the ''Qasser al-Yahud'' baptism site (740992E, 3525198N UTM Z36) in the Lower Jordan River, including an automatic water sampler (Andress and Hauser Liquiport 2000), and an independent EC-sensor (Condumax CLS12). In total, 428 water samples representing the time period 2010/03/26- 2012/07/09 were collected, filtered (0.22 µm PVDF) and analyzed for anions (Cl, Br, NO3, SO4) applying IC Dionex DX-320 and for cations (Na, K, Mg, Ca) applying IC Dionex DX-500, both with conductometric detection. |
| title | Water quality data of the Lower Jordan River 2010-2012 |
| topic | Automatic water sampler (Andress and Hauser Liquiport 2000); Bromide; Calcium; Chloride; Conductivity; CTD, Sea-Bird, SBE 911; DATE/TIME; Ion chromatograph, Dionex Corporation, DX-320; Ion chromatograph, Dionex Corporation, DX-500; Jordan, Israel, Asia; Jordan River; Magnesium; Nitrate; pollution; Potassium; Qasser_al-Yahud; Salinity; Sodium; Sulfate; water quality |
| url | https://doi.org/10.1594/PANGAEA.919103 |