I/Ca ratios in recent benthic foraminifera from the Peruvian OMZ (Q-ICP-MS data)
Fuente:
PANGAEA
Salvato in:
| Autore principale: | |
|---|---|
| Natura: | Dataset Open Access |
| Lingua: | en |
| Pubblicazione: |
PANGAEA
2020
|
| Soggetti: | |
| Accesso online: | |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1867168205004341248 |
|---|---|
| author | Glock, Nicolaas |
| author_facet | Glock, Nicolaas |
| collection | Datos científicos de ciencias marinas y ambientales |
| contents | Mean I/Ca ratios, number of measurements (n) and errors for recent benthic foraminifera at different sampling sites of the Peruvian oxygen minimum zone. The variability represents the standard deviation between all measurements of the sample/standard. In addition, core locations and bottom water oxygen concentrations (O2BW) are listed. I/Ca ratios were measured with Q-ICP-MS after the protocols described in Glock et al. (2014). Samples were taken during RV Meteor cruises M77/1 and M77/2 in the framework of the SFB754. |
| format | Dataset Open Access |
| id | pangaea_https___doi_org_10_1594_PANGAEA_919740 |
| institution | PANGAEA |
| language | en |
| publishDate | 2020 |
| publisher | PANGAEA |
| record_format | pangaea |
| spellingShingle | I/Ca ratios in recent benthic foraminifera from the Peruvian OMZ (Q-ICP-MS data) Glock, Nicolaas Benthic foraminifera; Climate - Biogeochemistry Interactions in the Tropical Ocean; Elevation of event; Event label; Iodine/Calcium ratio; Latitude of event; Longitude of event; M77/1; M77/1_406-1; M77/1_455-1; M77/1_459-1; M77/1_487-1; M77/1_516-1; M77/1_553-1; M77/1_565-1; M77/1_604-1; M77/2; M77/2_047-3; M77/2_723; Meteor (1986); MUC; MUC 21; MUC 25; MUC 38; MUC 60; MUC 74; MultiCorer; Multicorer with television; Number; OMZ; Oxygen; Peru; Precision; Q-ICP-MS (Agilent 7500); Sample code/label; SFB754; Species; TVMUC; Uncertainty Mean I/Ca ratios, number of measurements (n) and errors for recent benthic foraminifera at different sampling sites of the Peruvian oxygen minimum zone. The variability represents the standard deviation between all measurements of the sample/standard. In addition, core locations and bottom water oxygen concentrations (O2BW) are listed. I/Ca ratios were measured with Q-ICP-MS after the protocols described in Glock et al. (2014). Samples were taken during RV Meteor cruises M77/1 and M77/2 in the framework of the SFB754. |
| title | I/Ca ratios in recent benthic foraminifera from the Peruvian OMZ (Q-ICP-MS data) |
| topic | Benthic foraminifera; Climate - Biogeochemistry Interactions in the Tropical Ocean; Elevation of event; Event label; Iodine/Calcium ratio; Latitude of event; Longitude of event; M77/1; M77/1_406-1; M77/1_455-1; M77/1_459-1; M77/1_487-1; M77/1_516-1; M77/1_553-1; M77/1_565-1; M77/1_604-1; M77/2; M77/2_047-3; M77/2_723; Meteor (1986); MUC; MUC 21; MUC 25; MUC 38; MUC 60; MUC 74; MultiCorer; Multicorer with television; Number; OMZ; Oxygen; Peru; Precision; Q-ICP-MS (Agilent 7500); Sample code/label; SFB754; Species; TVMUC; Uncertainty |
| url | https://doi.org/10.1594/PANGAEA.919740 |