Diel cycling of Arsenic and Antimony in the Macleay River in October 2016

Fuente: PANGAEA
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Johnston, Scott G, Karimian, Niloofar, Burton, Edward
Format: Dataset Open Access
Sprache:en
Veröffentlicht: PANGAEA 2020
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1867171869803675648
author Johnston, Scott G
Karimian, Niloofar
Burton, Edward
author_facet Johnston, Scott G
Karimian, Niloofar
Burton, Edward
collection Datos científicos de ciencias marinas y ambientales
contents Diel sampling was conducted in a small pool in Bakers Creek (Macleay River), immediately upstream from the confluence with the main Macleay River trunk channel during October 2016. At the time of sampling, the pool was shallow (<0.7 m) and contained low-turbidity surface water overlying sandy-textured benthic sediments with abundant filamentous green algae (Spirogyra sp.) and a uniformly low flow (~0.01 m³/s). Water temperature, dissolved oxygen (DO), pH and redox potential were measured in situ at 5 minute intervals using a freshly calibrated EXO-2 multi-parameter sonde (YSI instruments). At each sampling interval (every 1.5-2 hrs), a 60 mL water sample was collected via a clean enclosed syringe and pre-cleaned PTFE tubing connected to a sampling port situated 0.1 m below the water surface and filtered immediately on-site (0.45 µm; enclosed syringe filter). Both syringe and tubing were pre-flushed (5x) prior to sample collection. Filtered aliquots were added to a 1,10-phenanthroline solution for subsequent photometric determination of Fe2+. Additional filtered sub-samples were collected and preserved for subsequent analysis of As3+ [via high performance liquid chromatography (HPLC; Perkin-Elmer Flexar) coupled with inductively coupled plasma mass spectrometry (ICP-MS; Perkin Elmer Nexion 350D), using a C18 (5 µm) column and mobile phase of 1 mM tetra-butyl ammonium hydroxide, 0.5 mM EDTA and 5% ethanol in de-ionized water (flow rate 1 mL min-1; 20 µL injection)] and Mn, Fe and Sb via ICP-MS.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_920580
institution PANGAEA
language en
publishDate 2020
publisher PANGAEA
record_format pangaea
spellingShingle Diel cycling of Arsenic and Antimony in the Macleay River in October 2016
Johnston, Scott G
Karimian, Niloofar
Burton, Edward
antimony; Antimony; arsenic; Arsenic; DATE/TIME; EXO2 Multisonde; High performance liquid chromatography (HPLC; Perkin-Elmer Flexar) coupled with inductively coupled plasma mass spectrometry (ICP-MS; Perkin Elmer Nexion 350D); Inductively coupled plasma mass spectrometer (ICP-MS), Perkin-Elmer, Nexion 350D; Iron; LATITUDE; LONGITUDE; Macleay_River; Macleay River; Manganese; MULT; Multiple investigations; Oxidation reduction (RedOx) potential; Oxygen, dissolved; pH; Redox potential; Temperature; Temperature, water; YSI_EXO
Diel sampling was conducted in a small pool in Bakers Creek (Macleay River), immediately upstream from the confluence with the main Macleay River trunk channel during October 2016. At the time of sampling, the pool was shallow (<0.7 m) and contained low-turbidity surface water overlying sandy-textured benthic sediments with abundant filamentous green algae (Spirogyra sp.) and a uniformly low flow (~0.01 m³/s). Water temperature, dissolved oxygen (DO), pH and redox potential were measured in situ at 5 minute intervals using a freshly calibrated EXO-2 multi-parameter sonde (YSI instruments). At each sampling interval (every 1.5-2 hrs), a 60 mL water sample was collected via a clean enclosed syringe and pre-cleaned PTFE tubing connected to a sampling port situated 0.1 m below the water surface and filtered immediately on-site (0.45 µm; enclosed syringe filter). Both syringe and tubing were pre-flushed (5x) prior to sample collection. Filtered aliquots were added to a 1,10-phenanthroline solution for subsequent photometric determination of Fe2+. Additional filtered sub-samples were collected and preserved for subsequent analysis of As3+ [via high performance liquid chromatography (HPLC; Perkin-Elmer Flexar) coupled with inductively coupled plasma mass spectrometry (ICP-MS; Perkin Elmer Nexion 350D), using a C18 (5 µm) column and mobile phase of 1 mM tetra-butyl ammonium hydroxide, 0.5 mM EDTA and 5% ethanol in de-ionized water (flow rate 1 mL min-1; 20 µL injection)] and Mn, Fe and Sb via ICP-MS.
title Diel cycling of Arsenic and Antimony in the Macleay River in October 2016
topic antimony; Antimony; arsenic; Arsenic; DATE/TIME; EXO2 Multisonde; High performance liquid chromatography (HPLC; Perkin-Elmer Flexar) coupled with inductively coupled plasma mass spectrometry (ICP-MS; Perkin Elmer Nexion 350D); Inductively coupled plasma mass spectrometer (ICP-MS), Perkin-Elmer, Nexion 350D; Iron; LATITUDE; LONGITUDE; Macleay_River; Macleay River; Manganese; MULT; Multiple investigations; Oxidation reduction (RedOx) potential; Oxygen, dissolved; pH; Redox potential; Temperature; Temperature, water; YSI_EXO
url https://doi.org/10.1594/PANGAEA.920580