U-series geochronology of travertine deposits of the Santa Fe fault zone of the Lucero Uplift, New Mexico, USA
Fuente:
PANGAEA
Salvato in:
| Autori principali: | , , , |
|---|---|
| Natura: | Dataset Open Access |
| Lingua: | en |
| Pubblicazione: |
PANGAEA
2021
|
| Soggetti: | |
| Accesso online: | |
| Tags: |
Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
|
| _version_ | 1867168207597469696 |
|---|---|
| author | Garcia, Victor Higareda Ma, Lin Ricketts, Jason William Dosseto, Anthony |
| author_facet | Garcia, Victor Higareda Ma, Lin Ricketts, Jason William Dosseto, Anthony |
| collection | Datos científicos de ciencias marinas y ambientales |
| contents | A total of 45 individual travertine samples were collected along a 10 km trace of the Santa Fe fault zone. Travertine samples were collected from low (Qtr1; basin floor), middle (Qtr2), and high (Qtr3; Lucero Uplift) elevations near east- and west-dipping faults and at the main exposures within the Santa Fe fault zone. Of these 45 samples, 25 representative samples were selected for geochronological and geochemical analyses. Travertine layers were micro-drilled to provide enough powder (~150 mg) for carbon, oxygen, and strontium isotope analyses. Here we show the δ13C, δ18O, and 87Sr/86Sr dataset for travertine samples. δ13C and δ18O samples were analyzed at the University of Kansas' KECK-NSF Paleoenvironmental and Environmental Laboratory using a Thermo Scientific Kiel IV Carbonate Device interfaced to the inlet of a ThermoFinnigan MAT 253 dual inlet mass spectrometer. Sr samples were analyzed at the Center for Earth and Environmental Isotope Research at the University of Texas at El Paso using a Nu Plasma multi-collector inductively coupled plasma mass spectrometer after Sr separated and purified using ion chromatography procedures. |
| format | Dataset Open Access |
| id | pangaea_https___doi_org_10_1594_PANGAEA_926495 |
| institution | PANGAEA |
| language | en |
| publishDate | 2021 |
| publisher | PANGAEA |
| record_format | pangaea |
| spellingShingle | U-series geochronology of travertine deposits of the Santa Fe fault zone of the Lucero Uplift, New Mexico, USA Garcia, Victor Higareda Ma, Lin Ricketts, Jason William Dosseto, Anthony 87Sr/86Sr; AGE; Age, error; C isotopes; Determined using Isoplot 3.7; Elevation of event; Event label; Laboratory code/label; Latitude of event; Longitude of event; Multi-Collector ICP-MS (MC-ICP-MS), Nu Plasma; New Mexico, United States of America; O isotopes; ROCK; Rock sample; Sample code/label; Sample ID; Santa_Fe_fault_TPL04; Santa_Fe_fault_TPL07; Santa_Fe_fault_TPL10; Santa_Fe_fault_TPL14; Santa_Fe_fault_TPL16; Santa_Fe_fault_TPL17; Santa_Fe_fault_TPL19; Santa_Fe_fault_TPL21; Santa_Fe_fault_TPL2-1; Santa_Fe_fault_TPL23; Santa_Fe_fault_TPL2-3; Santa_Fe_fault_TPL2-4; Santa_Fe_fault_TPL25; Santa_Fe_fault_TPL2-5; Santa_Fe_fault_TPL26; Santa_Fe_fault_TPL2-7; Santa_Fe_fault_TPL2-7BASE; Santa_Fe_fault_TPL30; Santa_Fe_fault_TPL31; Santa_Fe_fault_TPL34; Santa_Fe_fault_TPL35; Santa_Fe_fault_TPL35V; Santa_Fe_fault_TPL36; Santa_Fe_fault_TPL38; Santa_Fe_fault_TPL39; Thorium-230/Uranium-238 activity ratio; Thorium-230/Uranium-238 activity ratio, error; Thorium-232; Thorium-232/Uranium-238 activity ratio; Thorium-232/Uranium-238 activity ratio, error; Uranium-234/Uranium-238 activity ratio; Uranium-234/Uranium-238 activity ratio, error; Uranium-238; U-series A total of 45 individual travertine samples were collected along a 10 km trace of the Santa Fe fault zone. Travertine samples were collected from low (Qtr1; basin floor), middle (Qtr2), and high (Qtr3; Lucero Uplift) elevations near east- and west-dipping faults and at the main exposures within the Santa Fe fault zone. Of these 45 samples, 25 representative samples were selected for geochronological and geochemical analyses. Travertine layers were micro-drilled to provide enough powder (~150 mg) for carbon, oxygen, and strontium isotope analyses. Here we show the δ13C, δ18O, and 87Sr/86Sr dataset for travertine samples. δ13C and δ18O samples were analyzed at the University of Kansas' KECK-NSF Paleoenvironmental and Environmental Laboratory using a Thermo Scientific Kiel IV Carbonate Device interfaced to the inlet of a ThermoFinnigan MAT 253 dual inlet mass spectrometer. Sr samples were analyzed at the Center for Earth and Environmental Isotope Research at the University of Texas at El Paso using a Nu Plasma multi-collector inductively coupled plasma mass spectrometer after Sr separated and purified using ion chromatography procedures. |
| title | U-series geochronology of travertine deposits of the Santa Fe fault zone of the Lucero Uplift, New Mexico, USA |
| topic | 87Sr/86Sr; AGE; Age, error; C isotopes; Determined using Isoplot 3.7; Elevation of event; Event label; Laboratory code/label; Latitude of event; Longitude of event; Multi-Collector ICP-MS (MC-ICP-MS), Nu Plasma; New Mexico, United States of America; O isotopes; ROCK; Rock sample; Sample code/label; Sample ID; Santa_Fe_fault_TPL04; Santa_Fe_fault_TPL07; Santa_Fe_fault_TPL10; Santa_Fe_fault_TPL14; Santa_Fe_fault_TPL16; Santa_Fe_fault_TPL17; Santa_Fe_fault_TPL19; Santa_Fe_fault_TPL21; Santa_Fe_fault_TPL2-1; Santa_Fe_fault_TPL23; Santa_Fe_fault_TPL2-3; Santa_Fe_fault_TPL2-4; Santa_Fe_fault_TPL25; Santa_Fe_fault_TPL2-5; Santa_Fe_fault_TPL26; Santa_Fe_fault_TPL2-7; Santa_Fe_fault_TPL2-7BASE; Santa_Fe_fault_TPL30; Santa_Fe_fault_TPL31; Santa_Fe_fault_TPL34; Santa_Fe_fault_TPL35; Santa_Fe_fault_TPL35V; Santa_Fe_fault_TPL36; Santa_Fe_fault_TPL38; Santa_Fe_fault_TPL39; Thorium-230/Uranium-238 activity ratio; Thorium-230/Uranium-238 activity ratio, error; Thorium-232; Thorium-232/Uranium-238 activity ratio; Thorium-232/Uranium-238 activity ratio, error; Uranium-234/Uranium-238 activity ratio; Uranium-234/Uranium-238 activity ratio, error; Uranium-238; U-series |
| url | https://doi.org/10.1594/PANGAEA.926495 |