Isotope analyses of travertine deposits of the Santa Fe fault zone of the Lucero Uplift, New Mexico, USA

Fuente: PANGAEA
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Garcia, Victor Higareda, Ma, Lin, Ricketts, Jason William, Dosseto, Anthony
Format: Dataset Open Access
Sprache:en
Veröffentlicht: PANGAEA 2021
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1867169142991224832
author Garcia, Victor Higareda
Ma, Lin
Ricketts, Jason William
Dosseto, Anthony
author_facet Garcia, Victor Higareda
Ma, Lin
Ricketts, Jason William
Dosseto, Anthony
collection Datos científicos de ciencias marinas y ambientales
contents A total of 45 individual travertine samples were collected along a 10 km trace of the Santa Fe fault zone. Travertine samples were collected from low (Qtr1; basin floor), middle (Qtr2), and high (Qtr3; Lucero Uplift) elevations near east- and west-dipping faults and at the main exposures within the Santa Fe fault zone. Of these 45 samples, 25 representative samples were selected for geochronological and geochemical analyses. Travertine layers were micro-drilled to provide enough powder (~150 mg) for carbon, oxygen, and strontium isotope analyses. Here we show the δ13C, δ18O, and 87Sr/86Sr dataset for travertine samples. δ13C and δ18O samples were analyzed at the University of Kansas' KECK-NSF Paleoenvironmental and Environmental Laboratory using a Thermo Scientific Kiel IV Carbonate Device interfaced to the inlet of a ThermoFinnigan MAT 253 dual inlet mass spectrometer. Sr samples were analyzed at the Center for Earth and Environmental Isotope Research at the University of Texas at El Paso using a Nu Plasma multi-collector inductively coupled plasma mass spectrometer after Sr separated and purified using ion chromatography procedures.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_926500
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle Isotope analyses of travertine deposits of the Santa Fe fault zone of the Lucero Uplift, New Mexico, USA
Garcia, Victor Higareda
Ma, Lin
Ricketts, Jason William
Dosseto, Anthony
87Sr/86Sr; C isotopes; Elevation of event; Event label; Laboratory code/label; Latitude of event; Longitude of event; Mass spectrometer, Finnigan, MAT 253; coupled with Carbonate preparation device, Finnigan, KIEL IV; Multi-Collector ICP-MS (MC-ICP-MS), Nu Plasma; New Mexico, United States of America; O isotopes; ROCK; Rock sample; Sample code/label; Sample ID; Santa_Fe_fault_TPL04; Santa_Fe_fault_TPL07; Santa_Fe_fault_TPL10; Santa_Fe_fault_TPL14; Santa_Fe_fault_TPL16; Santa_Fe_fault_TPL17; Santa_Fe_fault_TPL19; Santa_Fe_fault_TPL21; Santa_Fe_fault_TPL2-1; Santa_Fe_fault_TPL23; Santa_Fe_fault_TPL2-3; Santa_Fe_fault_TPL2-4; Santa_Fe_fault_TPL25; Santa_Fe_fault_TPL2-5; Santa_Fe_fault_TPL26; Santa_Fe_fault_TPL2-7; Santa_Fe_fault_TPL2-7BASE; Santa_Fe_fault_TPL30; Santa_Fe_fault_TPL31; Santa_Fe_fault_TPL34; Santa_Fe_fault_TPL35; Santa_Fe_fault_TPL35V; Santa_Fe_fault_TPL36; Santa_Fe_fault_TPL38; Santa_Fe_fault_TPL39; Strontium-87/Strontium-86 ratio; Strontium-87/Strontium-86 ratio, error; U-series; δ13C; δ13C, standard error; δ18O; δ18O, standard error
A total of 45 individual travertine samples were collected along a 10 km trace of the Santa Fe fault zone. Travertine samples were collected from low (Qtr1; basin floor), middle (Qtr2), and high (Qtr3; Lucero Uplift) elevations near east- and west-dipping faults and at the main exposures within the Santa Fe fault zone. Of these 45 samples, 25 representative samples were selected for geochronological and geochemical analyses. Travertine layers were micro-drilled to provide enough powder (~150 mg) for carbon, oxygen, and strontium isotope analyses. Here we show the δ13C, δ18O, and 87Sr/86Sr dataset for travertine samples. δ13C and δ18O samples were analyzed at the University of Kansas' KECK-NSF Paleoenvironmental and Environmental Laboratory using a Thermo Scientific Kiel IV Carbonate Device interfaced to the inlet of a ThermoFinnigan MAT 253 dual inlet mass spectrometer. Sr samples were analyzed at the Center for Earth and Environmental Isotope Research at the University of Texas at El Paso using a Nu Plasma multi-collector inductively coupled plasma mass spectrometer after Sr separated and purified using ion chromatography procedures.
title Isotope analyses of travertine deposits of the Santa Fe fault zone of the Lucero Uplift, New Mexico, USA
topic 87Sr/86Sr; C isotopes; Elevation of event; Event label; Laboratory code/label; Latitude of event; Longitude of event; Mass spectrometer, Finnigan, MAT 253; coupled with Carbonate preparation device, Finnigan, KIEL IV; Multi-Collector ICP-MS (MC-ICP-MS), Nu Plasma; New Mexico, United States of America; O isotopes; ROCK; Rock sample; Sample code/label; Sample ID; Santa_Fe_fault_TPL04; Santa_Fe_fault_TPL07; Santa_Fe_fault_TPL10; Santa_Fe_fault_TPL14; Santa_Fe_fault_TPL16; Santa_Fe_fault_TPL17; Santa_Fe_fault_TPL19; Santa_Fe_fault_TPL21; Santa_Fe_fault_TPL2-1; Santa_Fe_fault_TPL23; Santa_Fe_fault_TPL2-3; Santa_Fe_fault_TPL2-4; Santa_Fe_fault_TPL25; Santa_Fe_fault_TPL2-5; Santa_Fe_fault_TPL26; Santa_Fe_fault_TPL2-7; Santa_Fe_fault_TPL2-7BASE; Santa_Fe_fault_TPL30; Santa_Fe_fault_TPL31; Santa_Fe_fault_TPL34; Santa_Fe_fault_TPL35; Santa_Fe_fault_TPL35V; Santa_Fe_fault_TPL36; Santa_Fe_fault_TPL38; Santa_Fe_fault_TPL39; Strontium-87/Strontium-86 ratio; Strontium-87/Strontium-86 ratio, error; U-series; δ13C; δ13C, standard error; δ18O; δ18O, standard error
url https://doi.org/10.1594/PANGAEA.926500