_version_ 1867171873567014912
author Goussin, Fanny
Guillot, Stéphane
Ruffet, Gilles
Poujol, Marc
Oliot, Émilien
Replumaz, Anne
Cordier, Carole
Dupont-Nivet, Guillaume
Roperch, Pierrick
author_facet Goussin, Fanny
Guillot, Stéphane
Ruffet, Gilles
Poujol, Marc
Oliot, Émilien
Replumaz, Anne
Cordier, Carole
Dupont-Nivet, Guillaume
Roperch, Pierrick
collection Datos científicos de ciencias marinas y ambientales
contents Deformed samples from the Yushu mélange, in the western Jinsha Suture, have been dated by U-Pb isotopy on zircons. This dataset presents U-Pb isotopy data obtained for these samples. The rock sample was crushed using standard procedures. The zircon grains were handpicked from the 80-200 micrometer non-magnetic fraction, placed on epoxy mounts and polished. Back-scattered electron images of the grains were acquired with a Hitachi S2500 Scanning Electron Microprobe at the Institut des Sciences de la Terre (ISTerre) of Grenoble (France). U-Pb zircon analyses were performed by in-situ LA-ICP-MS, using an ESI NWR193UC excimer laser coupled to a quadrupole Agilent 7700x ICP-MS at the GeOHeLiS analytical Platform (OSUR, Univ. Rennes). The diameter of the ablation spots varies from 20 to 30 µm, depending on the grain size. The repetition rate of the ablation was 3 Hz. Data were corrected for U-Pb and Th-Pb fractionation and for mass bias by repeated measurements of the standard GJ-1 (Jackson et al., 2004). Accuracy was monitored by analyses of the standard Plešovice (337.13 ± 0.37 Ma, Sláma et al., 2008), which produced a concordia age of 337.1 ± 2.1 Ma (N=18; MSWD=0.65) during the course of the analyses. Data reduction was carried out using the software Iolite v4 (Paton et al., 2010, 2011). The concordia ages and diagrams were generated using IsoplotR (Vermeesch, 2018). The full instrumental and analytical conditions can be found in Table "Operating conditions for the LA-ICP-MS equipment" and in Nosenzo et al. (2022).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_928990
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle U-Pb isotopy data of deformed samples from the Yushu mélange, western Jinsha Suture
Goussin, Fanny
Guillot, Stéphane
Ruffet, Gilles
Poujol, Marc
Oliot, Émilien
Replumaz, Anne
Cordier, Carole
Dupont-Nivet, Guillaume
Roperch, Pierrick
Age, 206Pb/238U Lead-Uranium; Age, 207Pb/206Pb Lead-Lead; Age, 207Pb/235U Lead-Uranium; Age, error; Age, mineral; Comment; Correlation coefficient, isotope ratio error; Description; Identification; Jinsha Suture; Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS); Lead; Lead-206; Lead-206/Uranium-238 ratio; Lead-206/Uranium-238 ratio, error, relative; Lead-207/Uranium-235 ratio; Lead-207/Uranium-235 ratio, error, relative; Percentage; ROCK; Rock sample; Thorium/Uranium ratio; U-Pb isotopy; Uranium; YU-14-63B; Yushu mélange
Deformed samples from the Yushu mélange, in the western Jinsha Suture, have been dated by U-Pb isotopy on zircons. This dataset presents U-Pb isotopy data obtained for these samples. The rock sample was crushed using standard procedures. The zircon grains were handpicked from the 80-200 micrometer non-magnetic fraction, placed on epoxy mounts and polished. Back-scattered electron images of the grains were acquired with a Hitachi S2500 Scanning Electron Microprobe at the Institut des Sciences de la Terre (ISTerre) of Grenoble (France). U-Pb zircon analyses were performed by in-situ LA-ICP-MS, using an ESI NWR193UC excimer laser coupled to a quadrupole Agilent 7700x ICP-MS at the GeOHeLiS analytical Platform (OSUR, Univ. Rennes). The diameter of the ablation spots varies from 20 to 30 µm, depending on the grain size. The repetition rate of the ablation was 3 Hz. Data were corrected for U-Pb and Th-Pb fractionation and for mass bias by repeated measurements of the standard GJ-1 (Jackson et al., 2004). Accuracy was monitored by analyses of the standard Plešovice (337.13 ± 0.37 Ma, Sláma et al., 2008), which produced a concordia age of 337.1 ± 2.1 Ma (N=18; MSWD=0.65) during the course of the analyses. Data reduction was carried out using the software Iolite v4 (Paton et al., 2010, 2011). The concordia ages and diagrams were generated using IsoplotR (Vermeesch, 2018). The full instrumental and analytical conditions can be found in Table "Operating conditions for the LA-ICP-MS equipment" and in Nosenzo et al. (2022).
title U-Pb isotopy data of deformed samples from the Yushu mélange, western Jinsha Suture
topic Age, 206Pb/238U Lead-Uranium; Age, 207Pb/206Pb Lead-Lead; Age, 207Pb/235U Lead-Uranium; Age, error; Age, mineral; Comment; Correlation coefficient, isotope ratio error; Description; Identification; Jinsha Suture; Laser-ablation inductively coupled plasma mass spectrometer (LA-ICP-MS); Lead; Lead-206; Lead-206/Uranium-238 ratio; Lead-206/Uranium-238 ratio, error, relative; Lead-207/Uranium-235 ratio; Lead-207/Uranium-235 ratio, error, relative; Percentage; ROCK; Rock sample; Thorium/Uranium ratio; U-Pb isotopy; Uranium; YU-14-63B; Yushu mélange
url https://doi.org/10.1594/PANGAEA.928990