Soil Temperature and Relative Humidity at the Yungay Hiperarid site, Atacama Desert, Chile 2015-2017

Fuente: PANGAEA
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Pfeiffer, Marco, Amundson, Ronald, Jordan, Teresa E
Format: Dataset Open Access
Langue:en
Publié: PANGAEA 2021
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1867169518518796288
author Pfeiffer, Marco
Amundson, Ronald
Jordan, Teresa E
author_facet Pfeiffer, Marco
Amundson, Ronald
Jordan, Teresa E
collection Datos científicos de ciencias marinas y ambientales
contents In August of 2015, soil relative humidity (RH) and temperature sensors were installed in a depth profile at the Yungay soil, a well known location in the hyperarid core of the Atacama Desert, previously examined in numerous publications (e.g. Ewing et al., 2006, 2008; Jungers et al., 2014). Ten HOBO Prov2 (U23-002) relative humidity (RH) and temperature sensors were placed in the soil at Yungay in August 2015. A 80 cm trench was dug, and a drill was used to emplace sensors at depths of 1, 5, 10, 20, 30, 40, 50, 60, 70 and 80 cm in the trench wall. Sensors where placed 15 cm from the trench wall and backfilled with soil to isolate from the trench microclimate. Upon refilling, soil RH and temperature values were obtained at 30 minutes intervals. The data records from August-22-2015 to November-11-2016 and from between June-26-2017 to October-15-2017.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_929564
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle Soil Temperature and Relative Humidity at the Yungay Hiperarid site, Atacama Desert, Chile 2015-2017
Pfeiffer, Marco
Amundson, Ronald
Jordan, Teresa E
Hyperarid soil; relative humidity; Temperature
In August of 2015, soil relative humidity (RH) and temperature sensors were installed in a depth profile at the Yungay soil, a well known location in the hyperarid core of the Atacama Desert, previously examined in numerous publications (e.g. Ewing et al., 2006, 2008; Jungers et al., 2014). Ten HOBO Prov2 (U23-002) relative humidity (RH) and temperature sensors were placed in the soil at Yungay in August 2015. A 80 cm trench was dug, and a drill was used to emplace sensors at depths of 1, 5, 10, 20, 30, 40, 50, 60, 70 and 80 cm in the trench wall. Sensors where placed 15 cm from the trench wall and backfilled with soil to isolate from the trench microclimate. Upon refilling, soil RH and temperature values were obtained at 30 minutes intervals. The data records from August-22-2015 to November-11-2016 and from between June-26-2017 to October-15-2017.
title Soil Temperature and Relative Humidity at the Yungay Hiperarid site, Atacama Desert, Chile 2015-2017
topic Hyperarid soil; relative humidity; Temperature
url https://doi.org/10.1594/PANGAEA.929564