Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018)

Fuente: PANGAEA
Salvato in:
Dettagli Bibliografici
Autori principali: Huhn, Oliver, Rhein, Monika, Bulsiewicz, Klaus, Sültenfuß, Jürgen
Natura: Dataset Open Access
Lingua:en
Pubblicazione: PANGAEA 2021
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867169145235177472
author Huhn, Oliver
Rhein, Monika
Bulsiewicz, Klaus
Sültenfuß, Jürgen
author_facet Huhn, Oliver
Rhein, Monika
Bulsiewicz, Klaus
Sültenfuß, Jürgen
collection Datos científicos de ciencias marinas y ambientales
contents Noble gases (3He, 4He, 20Ne, 22Ne) The water samples for stable noble gas isotopes (3He, 4He, 20Ne, 22Ne) were stored from the CTD/water bottle system without contact to atmospheric air and preventing air bubbles into gas tight copper tubes, which are clamped of at both sides. In the IUP Bremen noble gas lab the samples were pre-processed with a UHV (ultra high vacuum) gas extraction system. Sample gases are transferred via water vapor into a glass ampoule kept at liquid nitrogen temperature. For analysis of the noble gas isotopes the glass ampoules are connected to a fully automated UHV mass spectrometric system equipped with a two stage cryogenic system. Regularly, the system is calibrated with atmospheric air standards (reproducibility <0.2%). Also measurement of line blanks and linearity are done. The performance of the Bremen facility is described in Sültenfuß et al. (2009). The total errors for the noble gas measurements are estimated to be < 0.5 % for 4He, < 0.5 % for total Ne, and < 0.5% for δ3He Transient tracer (CFC-12, SF6) Chlorofluorocarbon (CFC-12) and sulfur hexafluoride (SF6) water samples from the CTD-bottle-system were stored in glass ampoules without contact to the atmosphere during the tapping. Immediately after sampling the ampoules are flame sealed after a CFC free headspace of pure nitrogen had been applied. The determination of concentrations in the IUP Bremen gas chromatography lab is accomplished by purge and trap sample pre-treatment followed by gas chromatographic (GC) separation on a capillary column and electron capture detection (ECD). The system is calibrated by analyzing several different volumes of a known standard gas. The loss of trace gas into the headspace is considered by a careful equilibration between liquid and gas phase under controlled conditions before the sealed ampoules are opened and a precise measurement of the volume of the headspace. Concentrations are calibrated on SIO98 scale (Prinn et al., 2000). A more detailed description of the measurement system is given by Bulsiewicz et at. (1998).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_930718
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018)
Huhn, Oliver
Rhein, Monika
Bulsiewicz, Klaus
Sültenfuß, Jürgen
Antarctica; ANT-XXXIII/2; Bottle number; CFC12; CTD/Rosette; CTD-RO; Date/Time of event; DEPTH, water; Elevation of event; Event label; Freon-12 (dichlorodifluoromethane); Gas chromatographic (GC) separation on a capillary column, electron capture detection (ECD); He; Helium; Helium-4; Latitude of event; Lazarev Sea; Longitude of event; Ne; Neon; noblegas; Polarstern; Pressure, water; PS111; PS111_100-1; PS111_101-1; PS111_10-2; PS111_12-2; PS111_122-1; PS111_123-1; PS111_124-1; PS111_126-1; PS111_127-1; PS111_128-1; PS111_129-1; PS111_130-1; PS111_131-1; PS111_132-1; PS111_133-1; PS111_14-5; PS111_18-1; PS111_19-3; PS111_20-3; PS111_21-3; PS111_22-1; PS111_23-1; PS111_24-1; PS111_25-1; PS111_26-1; PS111_32-1; PS111_33-1; PS111_34-1; PS111_35-2; PS111_36-1; PS111_38-1; PS111_39-1; PS111_43-1; PS111_44-1; PS111_45-1; PS111_46-1; PS111_47-1; PS111_48-1; PS111_49-1; PS111_51-1; PS111_52-1; PS111_55-1; PS111_56-1; PS111_58-1; PS111_59-1; PS111_60-1; PS111_61-1; PS111_62-1; PS111_64-2; PS111_65-1; PS111_66-1; PS111_67-1; PS111_68-1; PS111_69-1; PS111_70-1; PS111_71-1; PS111_72-1; PS111_73-1; PS111_77-1; PS111_78-1; PS111_79-1; PS111_80-1; PS111_87-1; PS111_88-1; PS111_89-1; PS111_90-1; PS111_91-1; PS111_92-3; PS111_9-3; PS111_93-1; PS111_94-1; PS111_95-1; PS111_96-1; PS111_97-1; PS111_99-1; Quality flag; Quality flag according to WOCE; SF6; South Atlantic Ocean; Sulfur hexafluoride, SF6; transient tracer; Ultra high vacuum (UHV) mass spectrometry; Weddell Sea; δ Helium-3
Noble gases (3He, 4He, 20Ne, 22Ne) The water samples for stable noble gas isotopes (3He, 4He, 20Ne, 22Ne) were stored from the CTD/water bottle system without contact to atmospheric air and preventing air bubbles into gas tight copper tubes, which are clamped of at both sides. In the IUP Bremen noble gas lab the samples were pre-processed with a UHV (ultra high vacuum) gas extraction system. Sample gases are transferred via water vapor into a glass ampoule kept at liquid nitrogen temperature. For analysis of the noble gas isotopes the glass ampoules are connected to a fully automated UHV mass spectrometric system equipped with a two stage cryogenic system. Regularly, the system is calibrated with atmospheric air standards (reproducibility <0.2%). Also measurement of line blanks and linearity are done. The performance of the Bremen facility is described in Sültenfuß et al. (2009). The total errors for the noble gas measurements are estimated to be < 0.5 % for 4He, < 0.5 % for total Ne, and < 0.5% for δ3He Transient tracer (CFC-12, SF6) Chlorofluorocarbon (CFC-12) and sulfur hexafluoride (SF6) water samples from the CTD-bottle-system were stored in glass ampoules without contact to the atmosphere during the tapping. Immediately after sampling the ampoules are flame sealed after a CFC free headspace of pure nitrogen had been applied. The determination of concentrations in the IUP Bremen gas chromatography lab is accomplished by purge and trap sample pre-treatment followed by gas chromatographic (GC) separation on a capillary column and electron capture detection (ECD). The system is calibrated by analyzing several different volumes of a known standard gas. The loss of trace gas into the headspace is considered by a careful equilibration between liquid and gas phase under controlled conditions before the sealed ampoules are opened and a precise measurement of the volume of the headspace. Concentrations are calibrated on SIO98 scale (Prinn et al., 2000). A more detailed description of the measurement system is given by Bulsiewicz et at. (1998).
title Noble gas (He, Ne isotopes) and transient tracer (CFC-12, SF6) measurements from POLARSTERN cruise PS111 (Weddell Sea, 2018)
topic Antarctica; ANT-XXXIII/2; Bottle number; CFC12; CTD/Rosette; CTD-RO; Date/Time of event; DEPTH, water; Elevation of event; Event label; Freon-12 (dichlorodifluoromethane); Gas chromatographic (GC) separation on a capillary column, electron capture detection (ECD); He; Helium; Helium-4; Latitude of event; Lazarev Sea; Longitude of event; Ne; Neon; noblegas; Polarstern; Pressure, water; PS111; PS111_100-1; PS111_101-1; PS111_10-2; PS111_12-2; PS111_122-1; PS111_123-1; PS111_124-1; PS111_126-1; PS111_127-1; PS111_128-1; PS111_129-1; PS111_130-1; PS111_131-1; PS111_132-1; PS111_133-1; PS111_14-5; PS111_18-1; PS111_19-3; PS111_20-3; PS111_21-3; PS111_22-1; PS111_23-1; PS111_24-1; PS111_25-1; PS111_26-1; PS111_32-1; PS111_33-1; PS111_34-1; PS111_35-2; PS111_36-1; PS111_38-1; PS111_39-1; PS111_43-1; PS111_44-1; PS111_45-1; PS111_46-1; PS111_47-1; PS111_48-1; PS111_49-1; PS111_51-1; PS111_52-1; PS111_55-1; PS111_56-1; PS111_58-1; PS111_59-1; PS111_60-1; PS111_61-1; PS111_62-1; PS111_64-2; PS111_65-1; PS111_66-1; PS111_67-1; PS111_68-1; PS111_69-1; PS111_70-1; PS111_71-1; PS111_72-1; PS111_73-1; PS111_77-1; PS111_78-1; PS111_79-1; PS111_80-1; PS111_87-1; PS111_88-1; PS111_89-1; PS111_90-1; PS111_91-1; PS111_92-3; PS111_9-3; PS111_93-1; PS111_94-1; PS111_95-1; PS111_96-1; PS111_97-1; PS111_99-1; Quality flag; Quality flag according to WOCE; SF6; South Atlantic Ocean; Sulfur hexafluoride, SF6; transient tracer; Ultra high vacuum (UHV) mass spectrometry; Weddell Sea; δ Helium-3
url https://doi.org/10.1594/PANGAEA.930718