GDGT concentration and stable carbon isotope from Mackenzie Delta lakes

Fuente: PANGAEA
Salvato in:
Dettagli Bibliografici
Autori principali: Lattaud, Julie, De Jonge, Cindy, Elling, Felix J, Pearson, Ann, Eglinton, Timothy Ian
Natura: Dataset Open Access
Lingua:en
Pubblicazione: PANGAEA 2021
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867169518646722560
author Lattaud, Julie
De Jonge, Cindy
Elling, Felix J
Pearson, Ann
Eglinton, Timothy Ian
author_facet Lattaud, Julie
De Jonge, Cindy
Elling, Felix J
Pearson, Ann
Eglinton, Timothy Ian
collection Datos científicos de ciencias marinas y ambientales
contents Glycerol Dialkyl Glycerol Tetraethers (GDGTs) have been analyzed from lacustrine sediment cores (3 lakes) in the Mackenzie Delta (Northwestern Territories, Canada). The cores are covering the last 200 years. GDGT have been extracted using EDGE and separated over aluminium oxide column using dichloromethane:methanol (1:1), then filtered. They have been quantified using an internal standard on a HPLC (high precision liquid chromatograph). Their compound-specific 13C ratios have been measured at low resolution (~3 samples per cores) on a SWIM-IRMS (spooling-wire microcombustion device interfaced with an isotope-ratio mass spectrometer). Their values have been compared to 13C of the bulk and 13C of diplopten to assess their sources and the metabolism of their producers.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_931301
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle GDGT concentration and stable carbon isotope from Mackenzie Delta lakes
Lattaud, Julie
De Jonge, Cindy
Elling, Felix J
Pearson, Ann
Eglinton, Timothy Ian
Carbon isotopes; GDGT
Glycerol Dialkyl Glycerol Tetraethers (GDGTs) have been analyzed from lacustrine sediment cores (3 lakes) in the Mackenzie Delta (Northwestern Territories, Canada). The cores are covering the last 200 years. GDGT have been extracted using EDGE and separated over aluminium oxide column using dichloromethane:methanol (1:1), then filtered. They have been quantified using an internal standard on a HPLC (high precision liquid chromatograph). Their compound-specific 13C ratios have been measured at low resolution (~3 samples per cores) on a SWIM-IRMS (spooling-wire microcombustion device interfaced with an isotope-ratio mass spectrometer). Their values have been compared to 13C of the bulk and 13C of diplopten to assess their sources and the metabolism of their producers.
title GDGT concentration and stable carbon isotope from Mackenzie Delta lakes
topic Carbon isotopes; GDGT
url https://doi.org/10.1594/PANGAEA.931301