Chemical impurity distribtion (Na, Mg, Sr) in the EPICA Dome C ice core bags 1065 and 3092 and Talos Dome ice core bag 375-B1 obtained from 2D imaging with LA-ICP-MS

Fuente: PANGAEA
Salvato in:
Dettagli Bibliografici
Autori principali: Bohleber, Pascal, Roman, Marco, Šala, Martin, Delmonte, Barbara, Stenni, Barbara, Barbante, Carlo
Natura: Dataset Open Access
Lingua:en
Pubblicazione: PANGAEA 2021
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1867170109131325440
author Bohleber, Pascal
Roman, Marco
Šala, Martin
Delmonte, Barbara
Stenni, Barbara
Barbante, Carlo
author_facet Bohleber, Pascal
Roman, Marco
Šala, Martin
Delmonte, Barbara
Stenni, Barbara
Barbante, Carlo
collection Datos científicos de ciencias marinas y ambientales
contents Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) offers micron-resolution 2D chemical imaging, which has been adapted recently to ice core analysis. Measurements were performed in 2020 at the Ca'Foscari University of Venice, in order to investigate the localization of impurities in the ice samples. Here images are presented from applying LA-ICP-MS elemental imaging to a samples of the EPICA Dome C ice core and the Talos Dome ice core from Antarctica. Lateral resolution is 35 microns both along and perpendicular to the scan direction. Considered as analytes are Na, Mg and Sr. Background and drift correction as well as image construction were performed using the software HDIP (Teledyne Photon Machines, Bozeman, MT, USA). Impurity images are acquired as a pattern of lines, without overlap in the direction perpendicular to that of the scan, and without any further spatial interpolation. Each pixel in an ice core chemical image has a size of 35 μm x 35 μm. For each chemical element the datasets comprise a numerical matrix which contains rows and columns according to the physical size of the image: an image of 7 mm x 35 mm in size has 200 rows and 1000 columns. The numerical entries in this matrix refer to the recorded intensity (e.g. in counts). Values lower than the detection limit are set to zero. Due to the careful synchronization, the individual pixels of the different chemical channels can be considered to be almost perfectly spatially aligned. In contrast, the mosaic of visual images obtained from the laser camera is not a-priori aligned with the chemical images. The visual images are generally characterized by air bubbles (dark blobs), grain boundaries (dark lines) and occasional sub-grain boundaries (thin dark lines).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_933333
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle Chemical impurity distribtion (Na, Mg, Sr) in the EPICA Dome C ice core bags 1065 and 3092 and Talos Dome ice core bag 375-B1 obtained from 2D imaging with LA-ICP-MS
Bohleber, Pascal
Roman, Marco
Šala, Martin
Delmonte, Barbara
Stenni, Barbara
Barbante, Carlo
Antarctica; Binary Object; Chemical impurities; DomeC; DRILL; Drilling/drill rig; Event label; File content; Ice core; ICEDRILL; Ice drill; LA-ICP-MS; TALDICE; Talos_Dome
Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) offers micron-resolution 2D chemical imaging, which has been adapted recently to ice core analysis. Measurements were performed in 2020 at the Ca'Foscari University of Venice, in order to investigate the localization of impurities in the ice samples. Here images are presented from applying LA-ICP-MS elemental imaging to a samples of the EPICA Dome C ice core and the Talos Dome ice core from Antarctica. Lateral resolution is 35 microns both along and perpendicular to the scan direction. Considered as analytes are Na, Mg and Sr. Background and drift correction as well as image construction were performed using the software HDIP (Teledyne Photon Machines, Bozeman, MT, USA). Impurity images are acquired as a pattern of lines, without overlap in the direction perpendicular to that of the scan, and without any further spatial interpolation. Each pixel in an ice core chemical image has a size of 35 μm x 35 μm. For each chemical element the datasets comprise a numerical matrix which contains rows and columns according to the physical size of the image: an image of 7 mm x 35 mm in size has 200 rows and 1000 columns. The numerical entries in this matrix refer to the recorded intensity (e.g. in counts). Values lower than the detection limit are set to zero. Due to the careful synchronization, the individual pixels of the different chemical channels can be considered to be almost perfectly spatially aligned. In contrast, the mosaic of visual images obtained from the laser camera is not a-priori aligned with the chemical images. The visual images are generally characterized by air bubbles (dark blobs), grain boundaries (dark lines) and occasional sub-grain boundaries (thin dark lines).
title Chemical impurity distribtion (Na, Mg, Sr) in the EPICA Dome C ice core bags 1065 and 3092 and Talos Dome ice core bag 375-B1 obtained from 2D imaging with LA-ICP-MS
topic Antarctica; Binary Object; Chemical impurities; DomeC; DRILL; Drilling/drill rig; Event label; File content; Ice core; ICEDRILL; Ice drill; LA-ICP-MS; TALDICE; Talos_Dome
url https://doi.org/10.1594/PANGAEA.933333