Saved in:
Bibliographic Details
Main Authors: Krisch, Stephan, Roig, Stéphane, Lodeiro, Pablo Fernandez, Yong, Jaw-Chuen, Herzberg, Nicola, Evers, Florian, Achterberg, Eric Pieter, Steffens, Tim
Format: Dataset Open Access
Language:en
Published: PANGAEA 2021
Subjects:
Online Access:https://doi.org/10.1594/PANGAEA.933431
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867171876278632448
author Krisch, Stephan
Roig, Stéphane
Lodeiro, Pablo Fernandez
Yong, Jaw-Chuen
Herzberg, Nicola
Evers, Florian
Achterberg, Eric Pieter
Steffens, Tim
author_facet Krisch, Stephan
Roig, Stéphane
Lodeiro, Pablo Fernandez
Yong, Jaw-Chuen
Herzberg, Nicola
Evers, Florian
Achterberg, Eric Pieter
Steffens, Tim
collection Datos científicos de ciencias marinas y ambientales
contents This dataset contains measured dissolved trace element concentrations (Fe, Mn, Co, Ni, Cu, Zn, Cd and Pb) of station depth profiles sampled in Fram Strait (North Greenland Sea) during GEOTRACES expedition GN05 (PS100) between 21 July and 1 September 2016. Samples were collected strictly following GEOTRACES guidelines (Cutter et al., 2017; https://www.geotraces.org) and analysed exactly as per Rapp et al., 2017 ( Anal. Chim. Acta; doi:10.1016/j.aca.2017.05.008). Concentrations were intercalibrated with GEOTRACES reference materials SAFe S and GSC (Bruland Research Lab), with exception of dissolved Cd data. Information on the analytical procedure including reference materials and limits of detection can be found in related published manuscripts, the PhD thesis of Stephan Krisch (Christian-Albrechts-Universität zu Kiel) or can be obtained from the authors upon request. Table caption: Measured concentrations of dissolved trace elements in Fram Strait sampled during GEOTRACES expedition GN05 (PS100) between 21 July-1 September 2006. Uncertainty is calculated as one standard deviation (1σ, STD) to replicate measurements via ICP-MS. ND = no data. Use of quality flags (QF) according to GEOTRACES policy (https://www.geotraces.org/geotraces-quality-flag-policy/). Plesae note, dissolved Cd data is not quality controlled. Somes samples were pooled (indicated in column "Bottle") from different bottles at one depth; the concentrations reflects the mean and the corresponding uncertainty is calculated as the standard deviation to replicate measurements. Trace metal concentrations at station 24 may show larger variations between different bottles at one specific depth. Because station 24 is located at Dijmphna Sund entrance sill, we associate these discrepancies to the water column's strong lateral and vertical turbulence (see ucCTD physical oceanography data) (e.g. Mortensen et al. 2011, 2013, Carroll et al. 2017) that goes in hand with localized TM aggregation-dissolution and sediment resuspension processes, thus affecting TM fractionation (e.g. Homoky et al. 2012).
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_933431
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle Dissolved trace elements (Fe, Mn, Co, Ni, Cu, Zn, Cd and Pb) measured on water bottle samples from ultra clean CTD/Water sampler-system during POLARSTERN cruise PS100 / GN05 (ARK-XXX/2)
Krisch, Stephan
Roig, Stéphane
Lodeiro, Pablo Fernandez
Yong, Jaw-Chuen
Herzberg, Nicola
Evers, Florian
Achterberg, Eric Pieter
Steffens, Tim
Arctic; ARK-XXX/2, GN05; Bottle number; Cadmium, dissolved; Cadmium, dissolved, standard deviation; calculated, 1 sigma; Cobalt, dissolved; Cobalt, dissolved, standard deviation; Copper, dissolved; Copper, dissolved, standard deviation; Cruise/expedition; CTD/Rosette, ultra clean; CTD-UC; Date/Time of event; DEPTH, water; Elevation of event; Event label; Fram Strait; GEOTRACES; Global marine biogeochemical cycles of trace elements and their isotopes; GN05; Greenland Sea; Inductively coupled plasma - mass spectrometry (ICP-MS); Iron, dissolved; Iron, dissolved, standard deviation; Latitude of event; Lead, dissolved; Lead, standard deviation; Longitude of event; Manganese, dissolved; Manganese, dissolved, standard deviation; micronutrients; Nickel, dissolved; Nickel, dissolved, standard deviation; North Greenland Sea; Polarstern; PS100; PS100/013-1; PS100/015-1; PS100/021-1; PS100/028-1; PS100/033-1; PS100/037-1; PS100/042-1; PS100/044-1; PS100/053-2; PS100/056-1; PS100/074-1; PS100/082-1; PS100/090-1; PS100/094-1; PS100/101-1; PS100/102-1; PS100/103-2; PS100/135-1; PS100/165-1; PS100/189-1; PS100/202-1; PS100/214-1; PS100/241-1; PS100/262-1; PS100/274-2; PS100/280-1; PS100/288-1; Quality flag; Seadatanet flag: Data quality control procedures according to SeaDataNet (2010); Standard deviation, relative; Station label; trace elements; trace metals; Zinc, dissolved; Zinc, dissolved, standard deviation
This dataset contains measured dissolved trace element concentrations (Fe, Mn, Co, Ni, Cu, Zn, Cd and Pb) of station depth profiles sampled in Fram Strait (North Greenland Sea) during GEOTRACES expedition GN05 (PS100) between 21 July and 1 September 2016. Samples were collected strictly following GEOTRACES guidelines (Cutter et al., 2017; https://www.geotraces.org) and analysed exactly as per Rapp et al., 2017 ( Anal. Chim. Acta; doi:10.1016/j.aca.2017.05.008). Concentrations were intercalibrated with GEOTRACES reference materials SAFe S and GSC (Bruland Research Lab), with exception of dissolved Cd data. Information on the analytical procedure including reference materials and limits of detection can be found in related published manuscripts, the PhD thesis of Stephan Krisch (Christian-Albrechts-Universität zu Kiel) or can be obtained from the authors upon request. Table caption: Measured concentrations of dissolved trace elements in Fram Strait sampled during GEOTRACES expedition GN05 (PS100) between 21 July-1 September 2006. Uncertainty is calculated as one standard deviation (1σ, STD) to replicate measurements via ICP-MS. ND = no data. Use of quality flags (QF) according to GEOTRACES policy (https://www.geotraces.org/geotraces-quality-flag-policy/). Plesae note, dissolved Cd data is not quality controlled. Somes samples were pooled (indicated in column "Bottle") from different bottles at one depth; the concentrations reflects the mean and the corresponding uncertainty is calculated as the standard deviation to replicate measurements. Trace metal concentrations at station 24 may show larger variations between different bottles at one specific depth. Because station 24 is located at Dijmphna Sund entrance sill, we associate these discrepancies to the water column's strong lateral and vertical turbulence (see ucCTD physical oceanography data) (e.g. Mortensen et al. 2011, 2013, Carroll et al. 2017) that goes in hand with localized TM aggregation-dissolution and sediment resuspension processes, thus affecting TM fractionation (e.g. Homoky et al. 2012).
title Dissolved trace elements (Fe, Mn, Co, Ni, Cu, Zn, Cd and Pb) measured on water bottle samples from ultra clean CTD/Water sampler-system during POLARSTERN cruise PS100 / GN05 (ARK-XXX/2)
topic Arctic; ARK-XXX/2, GN05; Bottle number; Cadmium, dissolved; Cadmium, dissolved, standard deviation; calculated, 1 sigma; Cobalt, dissolved; Cobalt, dissolved, standard deviation; Copper, dissolved; Copper, dissolved, standard deviation; Cruise/expedition; CTD/Rosette, ultra clean; CTD-UC; Date/Time of event; DEPTH, water; Elevation of event; Event label; Fram Strait; GEOTRACES; Global marine biogeochemical cycles of trace elements and their isotopes; GN05; Greenland Sea; Inductively coupled plasma - mass spectrometry (ICP-MS); Iron, dissolved; Iron, dissolved, standard deviation; Latitude of event; Lead, dissolved; Lead, standard deviation; Longitude of event; Manganese, dissolved; Manganese, dissolved, standard deviation; micronutrients; Nickel, dissolved; Nickel, dissolved, standard deviation; North Greenland Sea; Polarstern; PS100; PS100/013-1; PS100/015-1; PS100/021-1; PS100/028-1; PS100/033-1; PS100/037-1; PS100/042-1; PS100/044-1; PS100/053-2; PS100/056-1; PS100/074-1; PS100/082-1; PS100/090-1; PS100/094-1; PS100/101-1; PS100/102-1; PS100/103-2; PS100/135-1; PS100/165-1; PS100/189-1; PS100/202-1; PS100/214-1; PS100/241-1; PS100/262-1; PS100/274-2; PS100/280-1; PS100/288-1; Quality flag; Seadatanet flag: Data quality control procedures according to SeaDataNet (2010); Standard deviation, relative; Station label; trace elements; trace metals; Zinc, dissolved; Zinc, dissolved, standard deviation
url https://doi.org/10.1594/PANGAEA.933431