Saved in:
Bibliographic Details
Main Author: Kaul, Norbert
Format: Dataset Open Access
Language:en
Published: PANGAEA 2021
Subjects:
Online Access:https://doi.org/10.1594/PANGAEA.936595
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867169519007432704
author Kaul, Norbert
author_facet Kaul, Norbert
collection Datos científicos de ciencias marinas y ambientales
contents We used the 6 m long Bremen heat flow probe also called Giant Heat Flow Probe (GHF). The heat probe is constructed in the classical “violin bow” design (Hyndman et al., 1979; Hartmann and Villinger, 2002, Villinger et al., 2010), with 21 thermistors distributed over an active length of 5.2 m in 0.26 m intervals mounted inside an oil filled hydraulic tube (O.D. 14 mm) which is attached to the strength member (O.D. 130 mm). The sensor tube also contains a heater wire for the generation of high energy heat pulses of typically on the order of 800 J/m for in situ thermal conductivity measurements according to the pulsed needle probe method (Lister, 1979). A calibrated PT-100 seawater sensor on top of the weight stand allows to measure the absolute bottom water temperature and to check the calibration of the sensor string in deep water with high accuracy. Inclination and acceleration of the probe is measured to monitor the penetration process into the sediments and potential disturbances during the actual measurement period.
format Dataset Open Access
id pangaea_https___doi_org_10_1594_PANGAEA_936595
institution PANGAEA
language en
publishDate 2021
publisher PANGAEA
record_format pangaea
spellingShingle Heat flow data of RV SONNE cruise SO247
Kaul, Norbert
Center for Marine Environmental Sciences; MARUM
We used the 6 m long Bremen heat flow probe also called Giant Heat Flow Probe (GHF). The heat probe is constructed in the classical “violin bow” design (Hyndman et al., 1979; Hartmann and Villinger, 2002, Villinger et al., 2010), with 21 thermistors distributed over an active length of 5.2 m in 0.26 m intervals mounted inside an oil filled hydraulic tube (O.D. 14 mm) which is attached to the strength member (O.D. 130 mm). The sensor tube also contains a heater wire for the generation of high energy heat pulses of typically on the order of 800 J/m for in situ thermal conductivity measurements according to the pulsed needle probe method (Lister, 1979). A calibrated PT-100 seawater sensor on top of the weight stand allows to measure the absolute bottom water temperature and to check the calibration of the sensor string in deep water with high accuracy. Inclination and acceleration of the probe is measured to monitor the penetration process into the sediments and potential disturbances during the actual measurement period.
title Heat flow data of RV SONNE cruise SO247
topic Center for Marine Environmental Sciences; MARUM
url https://doi.org/10.1594/PANGAEA.936595